LEMCOM CANopen®
– User manual
Meaning
of indicator lights
COVAL
– LMCOP-EN-A-1155UM0068
13/49
4.1
Module Status (MS) indicator light
Red LED
Green
LED
Meaning
OFF
OFF
No power
: Check power supply connection.
OFF
Flashing
Standby
: Module not configured (e.g. no address assigned to a secondary
module).
OFF
ON
Operational
: The module is configured and working properly.
Flashing
OFF
Major recoverable fault
: Incorrect vacuum parameters, supply voltage fault,
internal temperature of module too high
ON
OFF
Critical unrecoverable fault
: Lost part, firmware fault
Flashing
Flashing
Self-test
: Running module startup phase
Table 2
– Indicator lights for overall module status
4.2
CAN-RUN and CAN-ERR indicator lights
The RUN (G3) and ERR (R1) indicator lights operate according to the DR-303-3 recommendations
of the CiA. These LEDs are used to determine the status of the CANopen communication.
LED states and flashing periods:
LED state
Description
OFF
Always off
ON
Always on
Fast flashing
Frequency = 10 Hz: 50 ms ON
– 50 ms OFF
Slow flashing
Frequency = 2.5 Hz: 200 ms ON
– 200 ms OFF
1 flash
1 short flash of 200 ms every second
2 flashes
2 short flashes of 200 ms separated by 200 ms every second
3 flashes
3 short flashes of 200 ms separated by 200 ms every second
Table 3
– States of the CAN-RUN and CAN-ERR LEDs
The
CAN-RUN
LED indicates the status of the product in relation to the NMT startup graph.
Figure 8
– CANopen NMT state machine (source: CiA)