12
ConteraIP Panoramic | Installation Manual
Wall Mount
For a proper wall mount installation, the AV-WMJB-W wall mount and CP-CAP-W wall mount cap are
required (sold separately). A wall mount should only be attached onto hard ceilings including wood,
plastic, metal, and concrete.
1. Using the Mounting template, prepare the mounting provisions for the camera installation.
2. Connect wall mount cap and wall mount.
NOTE: The thread size for Top shield, pendant pole and mount is 1.5” NPT.
3. Attach the wall mount to the wall using the four drywall screws provided or any optional hardware
suitable for the mounting surface.
4. Run the Ethernet cable and outside power cable (if necessary) through the wall mount. Ensure
the gasket is seated properly.
5. Use the supplied security L-key, to loosen the four (4) screws securing the dome cover. Do not
remove screws from the dome cover.