18
ConteraIP Panoramic | Installation Manual
Pole Mount
For a pole mount installation, the AV-WMJB-W wall mount, AV-PMA-W pole mount, and CP-CAP-
W mount cap are required (sold separately). A pole mount should only be attached onto hard
ceilings including wood, plastic, metal, and concrete.
1. Using the Mounting template, prepare the mounting provisions for the camera installation.
2. Connect the wall mount cap and wall mount.
3. Attach the Junction Box Adapter to the Pole Mount Adapter.
4.
Remove the conduit plug on the junction box adapter and connect ¾” NPT conduit to the junction
box adapter.
NOTE: Use silicon or water pipe seal tape to make sure no water leakage between
conduit pipe and junction box adapter.
5. Run the Ethernet cable and outside power cable (if necessary) through the Junction Box Adapter.
Ensure the gasket is seated properly.
6. Attach the Wall Mount Adapter (AV-WMJB-W) to the Pole Mount Adapter (AV-PMA-W).
Reference #
Description
1
Remove conduit plug
2
Connect ¾” NPT conduit to junction box
adapter (ensure use of water seal tape)