24
60T - 280T
COSMOGAS
C
B
A
020010.01.011
D
020010.01.012
Figure 5-1 - Disassembling transport pallet screws
5.1 - Choosing the installation site
ATTENTION !!! Do not store any flammable
material in the immediate vicinity of the appliance.
ATTENTION !!! Do not install the appliance on
carpeting.
ATTENTION !!! The appliance must be installed
in a room in which it can be supplied with air for
ventilation and combustion, whether that air is taken
from the outside (sealed combustion) or the inside
(combustion in ventilated chamber).
ATTENTION !!! Insufficient appliance ventilation
can cause high air temperatures.
ATTENTION !!! Make sure the intake and
exhaust openings are appropriately sized and that
there are no obstructions or clogs. If the problem is not
resolved, do not start the appliance. Please keep these
restrictions in mind, as well as the dangers they can
present to the operator.
ATTENTION !!! LP gas Liquefied Petroleum
gas - Installation requires special attention: LP gas
appliances must not be installed in pits, cellars or
similar locations where the gas, which is heavier than
air, could stagnate. Appliances with this kind of fuel
must not be installed in spaces under the level of the
floor or cellars. Failure to respect this precaution could
cause explosions and serious harm to people, death or
enormous material damage.
5 - INSTALLATION - Installation site
ATTENTION !!! Installing the appliance in rooms
with thin floors could create resonance noise. Install
elements that reduce the noise.
ATTENTION !!! Do not allow to much dust to
accumulate on the appliance.
ATTENTION !!! The appliance must only be
installed on solid flooring that supports the weight and
is level.
Before installing, wash the heating system and, if
necessary, the domestic hot water system thoroughly
in order to remove any residues or impurities that could
compromise proper appliance operation.
This appliance is not made to be installed in the open.
It must not be exposed to temperatures below zero or
above 50°C. Choose a location inside the home or, in
any case, sheltered from elements like rain, wind, sun
and, especially, frost.
This device must be installed in this sort of location so
that any water leaks coming from it, from the connections
between the pipes or from potential safety valve drainage
cannot damage materials or things underneath it.
Establish the appropriate room and position for installation,
keeping the following factors in mind:
- flue exhaust/air intake duct connection;
- gas adduction duct connection;
- water supply connection;
- centralised heating system connection;
- domestic hot water system connection (if present);
- electrical connection;
- connection of the condensate drain generated by the
boiler;
- room thermostat electrical connection;
- safety valve discharge connection;
- any external temperature sensor connection;
- room ventilation.