16
COSMOGAS
Ecotower
Figura 5-4 - ECOTOWER Hydraulic diagram with one heating/cooling circuit and DHW
LEGEND of Figure 5-4 and 5-5:
1 - Main electrical supply
2 - Power supply of the DHW electrical heater (1,5kW) (item
“20”)
6 - Power supply of the heating electrical heater (3kW) and
the integrative electrical heater (3kW) (item “33”)
7 - Outdoor unit
8 - Modbus communication
12 - Cooling demand
13 - Heating demand
15 - Circuit 1 sensor (TV1)
17 - Room temperature sensor (Tr). It must always be
connected and must be left inside the appliance.
18 - Heating/Cooling thermoregulation sensor (Tc)
19 - Indoor unit
20 - DHW integrative electrical heater (1,5kW) (section
8.2.10.2
21 - Oudoor unit power supply
22 - Safety kit (hydrometer, safety valve and automatic air vent
valve) (supplied with accessories)
23 - Domestic hot water outlet
24 - Cold water inlet
25 - Heating/cooling system filling
33 - Heating electrical heater (3 kW) and electrical heater
(3kW) inside the heat pump (section 8.2.10.1)
34 - Filter
35 - Heating/cooling system
36 - Expansion tank
38 - Differential by-pass valve
44 - Pressure safety relief valve (supplied with accessories)
5.3 - Ecotower with one heating/cooling circuit and DHW
5 - OPERATION