28
COSMOGAS
AGUAPLUS
10 - INSTALLATION - Electrical connections
10.1 - Electrical connections
WARNING !!! Disconnect power before carrying
out any operations inside the appliance.
WARNING !!! During maintenance, label all the
wires involved in the operation before disconnecting.
WARNING !!! The appliance is only electrically
safe when it is properly connected to a suitable earthing
system installed in accordance with the relevant
standards and regulations in force.
This fundamental safety requirement must be checked. In the
event of any doubt, ask for a full check of the electrical system
to be done by a qualified installer.
Have a professionally qualified electrician make sure that
the electrical system is appropriate to the electrical power
required by the appliance, shown on the plate.
The appliance must be connected to the electrical mains
through a fixed connection or through an unswitched plug
connection. The use of adapters, power strips, extension
cords, etc. is not allowed.
TThe appliance must be connected to the electrical mains
with a double insulated three-core cable or equivalent with
appropriate cross-section.
For the connection to the mains power supply 2-pole switch
must be provided in the vicinity of the appliance. This switch
must have a contact opening distance of at least 3 mm, as
expected by applicable standards in force.
Ensure that the polarity between live and neutral wires is
maintained when connecting the appliance.
Make sure that the water, central heating and gas system
pipes are not used as ground for the electrical or telephone
system. These pipes are not at all suitable for this purpose;
furthermore in a short time serious damage in terms of
corrosion could be noticed in the appliance and pipework.
WARNING !!! The appliance has no protections
against the effects of lightning strikes.
10.1.1 - Connecting power supply cable
To connect the electrical power supply cable, proceed as
follows (refer to Figure 10-1):
1.- Use a triple-pole dual insulation cable;
2.- Access the electrical connections terminals following the
specific instructions in section 15.2;
3.- Lay the power supply cable through the cable gland next
to contacts “101”, “102” and “PE”;
6.-Remove the sheathing from the cable, taking care to
keep the earth wire (yellow/green) 20 mm longer than the
other two;
7.- Connect the green-yellow cable to the ground terminal
(“PE”);
8.- Connect the brown cable (Phase) to terminal “101”;
9.- Connect the blue cable (Neutral) to terminal “102”;
A = Cable conduit
B = Line (hot) cable
C = Neutral cable
D = Ground cable
Figure 10-1 - Electrical connections box