19
AGUAPLUS
COSMOGAS
5.1 - Choosing the installation location
WARNING !!! Do not store any flammable
material in the immediate vicinity of the appliance.
WARNING !!! Do not install the appliance on
carpet.
WARNING !!! The appliance must be installed
in a room in which it can be supplied with air for
ventilation and combustion, regardless whether it is
taken from the outside (sealed combustion) or from
inside (combustion ventilated room).
WARNING !!! Inadequate ventilation of
appliance can cause elevated air temperatures.
5 - INSTALLATION - Place of installation
WARNING !!! Make sure that the intake and
outlet openings are the right sized and that there are
no obstructions or blockages. If the problem cannot be
resolved, do not start up the appliance.
WARNING !!! LP gas Liquefied Petroleum gas -
Installation requires special attention: LP gas appliances
must not be installed in pits, cellars or similar locations
where the gas, which is heavier than air, could stagnate.
Appliances with this kind of fuel must not be installed in
spaces under the level of the floor or cellars.
WARNING !!! The appliance must only be
installed on solid floor, which takes its weight and its
level.
Before installation, carefully wash out the system to remove
any possible residues or impurities that might compromise
operation of the appliance itself.
This appliance is not designed for direct outdoor
installation. It must not be exposed to temperatures
below zero or above 50°C. Choose a location inside the
home or, in any case, sheltered from elements like rain,
wind, sun and, especially, frost.
This appliance must be installed in a location so that any
water leaking from the appliance or piping connections
or relief valve opening will not cause damage to the area
surrounding the unit or any lower floor in the structure.
Determine the room and the right position for installation,
taking the following factors into account:
- connection to flue exhaust/air intake ducts;
- connection to gas pipe;
- water supply connection;
- domestic hot water system connection;
- electrical connection;
- connection to condensate drain;
- safety valve discharge connection;
- room ventilation.