61
AGUAPLUS
COSMOGAS
15 - MAINTENANCE
15.8 - Connecting the Display
to the other burners
In 100 to 140 appliances, being multi-burners, the display in
figure 14-1 is always connected directly to “Burner 1 (Master)”.
All the parameters that can be consulted on the display
(sections 14.8, 14.9 and 20) that refer to Burner 1 (Master)
exclusively concern this burner. If you wish to see/change the
same parameters for the other burners, you must move the
display connection from “Burner 1 (Master)” to the burner you
wish you view/edit; proceed as follows:
(refer to Figure 15-10):
Figure 15-10 Connecting the display in the other burners
A = Connector for Burner 1 (Master) dialogue
B = Connector from display
C = Connector for Burner 2 dialogue (Only in 100 and 140 models)
1. Disconnect power to the appliance;
2. Follow what is described in section 15.2 to access the inner
components;
3. Disconnect terminal “B” (coming from the display) from
terminal “A” (coming from “Burner 1 (Master)”);
4. Connect terminal “B” to terminal “C”, “D” or “E”, depending
on which burner you wish to view or edit, considering that:
terminal “C” is for “Burner 2”; terminal “D” is for “Burner 3”
and terminal “E” is for “Burner 4”
5. Once the terminal is connected to the burner to be checked,
repower the appliance and switch it on;
6. The display will now show all the information regarding the
connected burner. Make all consultations or modifications
following what is described in sections 14.8, 14.9 and 20.
7. Once the check is complete, reconnect terminal “B” to
terminal “A” as it was previously.
Burner 2
Burner 1
(Master)