72
COSMOGAS
AGUAPLUS
16 - TECHNICAL FEATURES
AGUAPLUS TECHNICAL FEATURES
UM
60
70
100
115
140
Type (Flue exhaust/air intake type)
B23 ; B3P
B23 ; B3P
Category
II2H3P
II2H3P
II2H3P
II2H3P
II2H3P
UE-type Certificate (PIN)
0476CR1272
0476CR1272
0476CR1272
0476CR1272
0476CR1272
Max heat capacity PCI (PCS)
kW
57,8 (64,2)
69,9 (77,6)
99,0 (109,9)
115,6 (128,3)
140,0 (155,4)
Minimum heat capacity PCI (PCS)
kW
12,0 (13,3)
14,7 (16,3)
12,0 (13,3)
12,0 (13,3)
14,7 (16,3)
Max output heat (50/30) “Pn”
kW
60,7
73,5
104,0
121,4
147,1
Efficiency at max output heat (50/30) PCI (PCS)
%
105,0 (94,6)
105,1 (94,7)
105,0 (94,6)
105,0 (94,6)
105,1 (94,7)
Minimum output heat (50/30) “Pm”
kW
12,8
15,6
12,8
12,8
15,6
Efficiency at minimum output heat (50/30) PCI (PCS)
%
106,6 (96,0)
106,3 (95,8)
106,6 (96,0)
106,6 (96,0)
106,3 (95,8)
Gas flow rate
G20
m
3
/h
6,11
7,39
10,47
12,22
14,80
G31
kg/h
4,49
5,43
7,68
8,97
10,87
Gas supply pressure
G20
mbar
20
20
20
20
20
G31
mbar
37
37
37
37
37
Gas supply minimum pressure
G20
mbar
10
10
10
10
10
G31
mbar
10
10
10
10
10
Gas supply maximum pressure
G20
mbar
45
45
45
45
45
G31
mbar
45
45
45
45
45
Main exchanger water content
l
4,6
5,7
9,2
9,2
11,4
Minimum operating water flow rate
l/h
0
0
0
0
0
Instantaneous d.h.w. production (dt 30°C)
l/min
29,2
35,3
50,0
58,4
70,7
D.H.W. adjustment range
°C
20 - 80
20 - 80
20 - 80
20 - 80
20 - 80
Maximum temperature for safety intervention
°C
95
95
95
95
95
Maximum water pressure
bar
11
11
11
11
11
Minimum water pressure
bar
1
1
1
1
1
Rated power supply voltage
V ~
230
230
230
230
230
Rated power supply frequency
Hz
50
50
50
50
50
Absorbed electrical power
W
432
472
542
542
622
Degree of electrical protection
IP21
IP21
IP21
IP21
IP21
Degree of electrical protection with outdoor covering
IPX5D
IPX5D
IPX5D
IPX5D
IPX5D