21
1. Regularly check whether the bolts and nuts of each part are fastened, whether the adjusting knob is
locked, whether the rotating part is flexible, and whether there are any worn or damaged parts.These
parts are in good condition, the safety of the equipment can be guaranteed;
2. Any worn or damaged parts should be immediately removed or sent to the maintenance center for
replacement.
3. Keep the equipment clean, but do not wipe it with acidic, alkaline or organic solutions.
Failure and trouble shooting:
Failure
Root cause
Solutions
Base un-flat
1. Ground is not flat or has sundries
2. The base was not leveled when the
frame was assembled.
1. Eliminate sundries
2. Loosen the rack connection bolt to level
the base, then tighten the bolt
3. Adjust eccentric foot cover of bottom tube
Handle unstable
Screw is loosen
Tighten the screw
Rotating parts
have abnormal
sound
Gap disturbance
Open the shroud to adjust
Low resistance
1. Reluctance gap increases
2. The spinner is damaged
3. Belt slip
1. Open the shroud to adjust;
2. Replace;
3. Open the shroud to adjust