Series of four flashes
A series of four flashes means that the overflow
sensor has been triggered at least once. The
third time these sensors is triggered the
operation is stopped. The alarm is persistent and
will not disappear until the machine has been
restarted. If the sensor was triggered
immediately at start- up the machine will not
start the turbine.
A probable cause to this alarm is that the
second, middle sensor does not work due to
collection of dirt. Stop the machine and
disconnect the power. Clean the machine in
accordance with this manual and try again. If the
alarm was presented immediately at start-up,
the overflow sensor could be clogged or
malfunctioning. Stop the machine and
disconnect the power. Clean the machine in
accordance with this manual and try again.
After finished job, dismount
When the job is finished, follow below instructions:
1.
Stop the turbine, turn it off.
2.
Push manual pump button to empty the WS4 ES.
3.
Turn the WS4 ES off and disconnect power.
4.
Disconnect hoses.
At a suitable location, loosen and remove the lid. With water, clean and empty the WS4 ES of all
collected dirt and dust. If it is dirty, replace the filter