© Corroventa Ltd.
2017.02
15 (15)
Turbine/Kombi
machine does not
start.
Depending on the situation:
Pump is active.
An alarm has been
triggered and stopped the
WS4 ES.
The turbine/Kombi machine
is not correctly connected or
started.
WS4 ES failure.
Trouble shoot as follows, given the situation:
Check to see if water is coming out through
the drainage hose. If so, the turbine will
resume when the WS4 ES has been emptied.
Check the WS4 ES alarm indicator. If it is
flashing, signaling an alarm, please refer to
paragraph Function and indicator signals.
Verify that it is connected to the power outlet
of the WS4 ES, that it is activated and that
there is power to the WS4 ES.
If the above has not helped, restart the WS4
ES and check that it, upon activation, gives a
short flash of the alarm indicator confirming
that it has not detected any errors. If so,
continue the trouble shooting with the
turbine/Kombi machine that may be the
cause of the problem. If not, contact your
retailer for service and repair:
Technical data
Max pump elevation (m)
3,5
Capacity (l/min)
25
Voltage
230 VAC / 50 Hz
Rated power (W)
700
Height x width x length (mm)
487 x 293 x 446
Weight, kg
20