RESERVED FOR QU
ALIFIED
TECHNICIANS
LIMIT STOP ADJUSTMENT PLAN 75 MOTOR
The end user of the product must refer to the limit stop
adjustment procedure described here below. This procedure
differs from the initial adjustment of the motor set by the
technical installer (see Installation Manual).
LIMIT SWITCH: OPENING (AWNING EXTENDED)
If the INSTALLATION KIT panel is present, connect it to the
motor so that it can be manoeuvred.
N.B. For those who don’t have a push-button panel ask a
qualified technician to realize one, as in the wiring
scheme.
Run down the awning to the pre-set position for the opening
limit switch; the awning must be in this position to set the
opening limit switch.
Push the
A*
button on the motor box using a screwdriver,
making a slight rotation, block the push-button in depressed
position. The actual limit switch will be cancelled.
When the push-button is pushed inside, operate the panel
until the awning is in the right limit switch position. Press push-
button
A
with a screwdriver and turn slightly to release, to
store the limit switch position and quit the procedure.
*
Do not try to force the push-button if it does not move when
pressed, but ensure that the motor is positioned on the limit
switch.
LIMIT SWITCH: CLOSING (AWNING RETRACTED)
Connect the panel to the motor. Raise the awning to the pre-
set position for the closing limit switch. The awning must be in
this position to set the closing limit switch. Press push-button
B
on the motor body with a screwdriver, turning it slightly in
order to secure the push-button.
When the push-button is pushed inside and secured, operate
the panel until the awning is in the right limit switch position.
Press push-button
B
with a screwdriver and turn slightly to
release, to store the limit switch position and quit the
procedure.
ADJUSTING THE COMMANDS
ELECTRIC DRIVE TYPE 1 (PLAN 75 MOTOR)
B
A
Panel
M1
1
2
3
1
3
2
insulated extend
button 230 V
A
B
Open male plug
supplied
insulated retract
button 230 V
WIRE TYPE
FG70R 3X1,5 mmq
WIRE TYPE
FG70R 3X1,5 mmq
W
ORK MUST BE C
ARRIED OUT B
Y
INST
A
LLER
PLAN 75 Motor
230 V/50 Hz
In= 0,97 A
Pn= 218 W
IP= 54
RETR
A
C
T
C
O
MMON
EX
TEND
ENGLISH
ESP
A
ÑOL
FR
ANÇ
A
IS
DEUT
S
CH
IT
ALIANO
2 - 04.2011
CORRADI S.P.A. - USER MANUAL - EXYL