Installation and service manual: Postmix tower
Ribbon
90
Cornelius Deutschland GmbH
Document no. TD0000100
Version: 06/11/2017, Index 0
4.
Drain the unit as follows:
a.
Empty the cleaning container.
b.
Close the valve of the water supply;
see docu-
mentation on the water system
.
c.
Keep dispensing beverages for each product
until only CO
2
comes out of the dispensing noz-
zle.
d.
Disconnect all basic ingredient/beverage tubes of
the undercounter cooler from the cleaning con-
tainer.
e.
Connect all basic ingredient/beverage tubes to
the undercounter cooler; see the document
“Undercounter cooler installation and service manual”
.
f.
Shut down the undercounter cooler; see the document
“Undercounter cooler
operator manual”
.
5.
Clean the outside of the unit; see the document
“Tower operator manual”, document no.
TD0000000
.
6.
Disconnect the unit from power,
.
Figure 165