53
Cornelius Deutschland GmbH
Document no. TD0000100
Version: 06/11/2017, Index 0
4.
Pull and lift the valve assembly out of the unit.
5.
Check all quad rings (Figure 65/2) of the valve assembly
(Figure 65/1) for damage.
Replace any damaged quad rings (Figure 65/2).
6.
Lubricate all quad rings (Figure 65/2) of the valve
assembly (Figure 65/1).
7.
Position the valve assembly within the unit.
8.
Attach the valve assembly (Figure 63/2) using the fas-
tening screws (Figure 63/1).
9.
Connect all necessary plugs and cables to the valve
assembly (Figure 62/1).
Finishing tasks
1.
Install the touchscreen,
Figure 64
2
1
Figure 65