![Cornelius 221000414x Installation And Service Manual Download Page 28](http://html1.mh-extra.com/html/cornelius/221000414x/221000414x_installation-and-service-manual_2667698028.webp)
Installation and service manual: Postmix tower
Ribbon
26
Cornelius Deutschland GmbH
Document no. TD0000100
Version: 06/11/2017, Index 0
2.
Feed the tubes and cables through the opening into the
supporting structure in a downward motion.
3.
Attach the unit to the supporting structure using threaded
bolts (Figure 17/3), nuts (Figure 17/2) and washers
(Figure 17/1), and tighten the nuts (Figure 17/2).
Check that the unit is properly attached. After attach-
ment, the unit must not tilt or overturn.
4.
Remove the caps from all tubes.
5.
Connect all tubes (Figure 18/1) to the python (Figure 18/
2) using push-in fittings.
Observe the labels on each individual tube as you con-
nect the tubes.
6.
Insert the retaining spring in accordance with the push-in
fitting instructions.
7.
Properly insulate the tubes.
8.
If applicable, install the drain set;
.
9.
Attach the panel (Figure 19/1),
10. Attach the drip tray (Figure 19/3) with grill,
Figure 16
Figure 17
3
2
1
Figure 18
1
2
Figure 19
2