CorDES Proprietary Information
13
CT Data Invert
Normal
Table 4-3 ECU Data Interface Settings
5
CONFIGURATION FOR OPERATION
This section provides detailed information about the CDNA remote management Human to
Machine Interface (HMI) application used to configure and view status of the CDNA-041G from
a workstation running Microsoft ® Windows 10 ® operating system. The management
application connects to the CNDA through an IPv4 Internet protocol (TCP/IP) Ethernet
connection over the
unit’s remote management connector.
A single workstation can be used to either control a single CDNA or control multiple CDNA units
as long as each unit is uniquely addressable via IPv4 over a local Ethernet network. The
management interface of the CDNA is set to request a dynamic IPv4 address via DHCP when
the unit boots up; therefore, there must be a DHCP server on the network. If static assignment
is preferred, simply reserve a static IP address in the servers DHCP pool bound to the CDNA
unit’s management MAC address. Multiple CDNA units are individually manageable via their
unique IPv4 addresses. IP port 10000 is the fixed management address of the management
interface. IP port 80 (HTTP) is for modifying the management controller (Lantronix Edge
device) PHY and should not be modified without consulting CorDes, LLC technical support
–
modifying parameters via HTTP may make the
unit’s management interface inaccessible.
5.1
Installing and Launching the HMI Application
The HMI Application is a desktop GUI
utility that runs on Windows 10™ and allows monitoring
and configuration of the CDNA over a local area network. The installer is distributed on a DVD;
simply run the cdna-hmi-app-win32-x64.msi to install the application on the management
computer.
Item
Name/Manufacturer/Model
Workstation
(Laptop or PC)
Intel® Core I3 or later Processor, 1.5 GHz minimum, 8 GB RAM minimum,
Software: x86-64 (64bit) Operating System - Windows 10 ®
Table 5-1 Hardware and Software Requirements
5.2
CDNA-041G Windows Overview
The CDNA remote management application provides basic configuration and status information
to the user. These features include:
•
Configuration of the CNDA-041G remote management interface.
•
Configuration of the CDNA-041G data plane interfaces.
•
View device level channel statistics