5
M801, M803, M804, M806 Programming
Turn ON Yellow LED verification on every Key Depression
99# Master Code*
Yellow LED blinks
30# 1# 1# (On) (0# = Off)
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
Set Time
99# Master Code*
Yellow LED blinks
41# hh:mm# (24hr Format) 0#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
24Hr Format => 1PM = 13:00, 2PM = 14:00.......10PM = 22:00, Midnight = 00:00, 1:15PM = 13:15
Daylight Savings Time
99# Master Code*
Yellow LED blinks
30# 13# 1# (On) (0# = Off)
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
Set Date (Today’s Date)
99# Master Code*
Yellow LED blinks
42# mmddyy# D.O.W.# (Sunday=1)
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
D.O.W. = Day of week
Set Unlock Time
99# Master Code or Supervisor Code*
Yellow LED blinks
11# (1-255 sec.)# 0#
Yellow LED blinks
*
Yellow LED blinks quickly
*
Yellow LED blinks slowly
*
Yellow LED goes out
The Unlock Time is adjustable for momentary operation. A 5 second unlock time is recommended to
extend battery life. Once unlock time is entered, it is the same for ALL users except Extended Users.