background image

I N S T A L L A T I O N

EW8310

Early Warning Electromagnetic Lock

ISEW8310

PCN15020

R03/17GR

Installation Instructions

Pre-Installation Instructions 

1.   This product must be installed according to all applicable 

building and life safety codes. All installations must be 

approved by the Authority Having Jurisdiction (AHJ).

2.   Due to the variety of mounting configurations available with 

this product, a survey and assessment of the physical area 

in which the product will be installed must be performed. 

3.   The door frame must be inspected and deemed structurally 

sound prior to installation of the electromagnetic lock. The 

structural integrity of the mounting surfaces must be strong 

enough to meet or exceed the holding force of the product. 

4.   The product must be protected from potential damage due 

to intruders or tampering. 

5.   The product should be installed in a location that will not 

hinder or create a potential safety hazard to authorized 

personnel accessing the protected area. 

6.   Because electromagnetic locks are used in a variety of 

applications and different door frame configurations, an 

experienced installer with knowledge of this product must 

make a determination of the optimal mounting method for 

this specific application. 

7.   The components, hardware, installation instructions and 

mounting template included with this product are intended 

for use on outswinging doors. 

8.   Do not install this product on the exterior of buildings.

9.  Do not use as a doorstop. This will void warranty. 

10.  Separate accessories not included with this product must be 

used in the following applications: 

 

 •  Narrow head jamb situations or center-hung doors 

 

 •  Wherever there is insufficient space on the door 

 

  

frame header to mount the lock 

 

 •  Hollow metal or wood frames where the door stop is  

  

not thick enough to allow the product to be installed 

 

 •  Wherever an obstruction in the door prevents    

  

installation of the armature plate at a proper height  

 •  Doors that do not permit the armature plate to be  

  

mounted low enough to meet the magnet surface 

 

Refer to the Product Accessories Guide section of the 

Installation Instructions for further information. Accessories 

may impact holding force. 

11.   Installation of this product should be done by an 

experienced installer with knowledge of this product. 

12.   A mechanical latching device is recommended in conjunction 

with the Early Warning 8310 to maintain security during a 

power failure.

NOTE: It is highly recommended that thread locking compound 

be applied to all screws during installation to reduce chance of 

screws loosening over extended time.

PLEASE DELIVER ALL INSTALLATION INSTRUCTIONS TO  

THE END-USER UPON COMPLETION OF THE INSTALLATION.

1.   Mount the electromagnetic lock to the door frame as 

outlined on the installation template included with the 

product. 

Armature Plate Mounting Notes: 

1) It is essential that this plate pivot slightly on the mounting 

bolt to allow proper alignment with the magnet surface.  If not 

aligned, the lock may lose holding force or not lock at all.

2) The rubber washer on the head of the mounting bolt should 

project slightly beyond the surface of the armature plate. It 

will expand when power is removed and break the air vacuum 

between the plate and magnet.  If removed or trimmed, the lock 

will appear to have some holding force even when power is 

removed.

For added safety, thread locking compound has been provided 

for the armature plate bolt and the four captive electromagnetic 

lock mounting screws.

WARNING: Improper installation, maintenance, inspection 
or usage of the product or any related accessories or parts 
may cause the electromagnetic lock, armature plate and 
associated hardware to disengage and fall, causing serious 
bodily injury and property damage. Rutherford Controls Int’l 
Inc. and/or Rutherford Controls Int’l Corp. will not be liable to 
the installer, purchaser, end user or anyone else for damage 
or injury to person or property due to improper installation, 
care, storage, handling, maintenance, inspection, abuse, 
misuse or act of God or nature involving this product or any 
related accessories or parts.
2.
   Route the power supply connecting wire through the door 

frame and into the wire access hole in the top of the magnet 

housing. Connecting wire should be of sufficient gauge for 

the lock being installed and the distance being run. See 

table for current draw specifications and wiring gauge chart.

3.  See system overview and switching options.

  © 2017 RUTHERFORD CONTROLS INT’L | dormakaba Group

WWW.RUTHERFORDCONTROLS.COM • PHONE: 1.800.265.6630 • FAX: 1.800.482.9795 • E-MAIL: [email protected]

Summary of Contents for EW8310

Page 1: ...n of this product should be done by an experienced installer with knowledge of this product 12 A mechanical latching device is recommended in conjunction with the Early Warning 8310 to maintain security during a power failure NOTE It is highly recommended that thread locking compound be applied to all screws during installation to reduce chance of screws loosening over extended time PLEASE DELIVER...

Page 2: ...second Remote Alarm Period if the pressure has been withdrawn the Local Alarm relay will return to the normal condition The light panel however will continue to flash red and green until reset The Remote Alarm relay will remain off until reset If pressure is reapplied to the door the system goes directly to the 30 second Remote Alarm Period activation of Local Alarm Relay If the door is forced ope...

Page 3: ...NG MARKS FOR CANADA AND THE U S These Marks are registered by Underwriters Laboratories Inc The minimum height of the registered trademark symbol shall be 3 64 of an inch When the overall diameter of the UL Mark is less than 3 8 of an inch the trademark symbol may be omitted if it is not legible to the naked eye The font for all letter forms is Helvetica Condensed Black except for the trademark sy...

Page 4: ...power wires black is negative and Red is positive Remote A Purple is common C Orange is normally closed NC Blue is normally open NO Local Grey is common C Green is normally open NO Pink is normally closed NC ORDER SEPARATELY RCI 960 MO RECOMMENDED ORDER SEPARATELY OPTIONAL REQUEST TO EXIT SWITCH RCI 970 0R 975 RECOMMENDED NC PINK NO GREEN LOCAL COMMON GREY AUDIO SELECT SOUND PATTERNS 7 8 OR 9 ONLY...

Page 5: ...ed by the access control device 2 The access control device must be set for fail safe operation Override Connection for two EW8310 units Reset Connection for two EW8310 units Reset and Override Wiring for Double Doors Diagram reflects status with power on and door opened Override Connection for two EW8310 units Reset Connection for two EW8310 units NOTE By using either remote relay and the local r...

Page 6: ...ices that may be installed Cannot remove the lock mounting bracket from top of magnet for installation Lock is installed but has no holding force at all Lock has enough holding force to lightly hold a screwdriver or set of pliers but door will not lock Lock is operating and locking but the armature plate is humming against the surface of the lock Lock is not releasing immediately upon removal of p...

Page 7: ...filler bars as the RCI standard 8310 Available in several different widths For use when an obstruction in the door prevents the installation of the armature plate at a proper height If the armature plate needs to be lowered then a spacer bar can be used to lower the lock from the frame Available in several different thickness For use with doors that do not permit the armature plate to be mounted l...

Page 8: ...10 1000 14 10 10 1500 12 10 Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12 10 10 10 300 16 12 12 10 10 400 14 12 10 500 14 10 10 750 12 10 1000 10 1500 10 Load Current 24V Load Current 12V Wire Gauge Chart courtesy of Electronic Locking Devices by John L Schum WIRE GAUGE SELECTIONS 20...

Reviews: