2
(617417440)
FM359 7/19
Access 800
™
Series
Keypad Programming Instructions
Locks
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
Copyright © 2018
-2019
Corbin Russwin, Inc., an ASSA ABLOY Group
company. All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
1
Overview
The Keypad Lock can support 100 (M800) / 2000
(M801 – M806) users. Each user is assigned a User
Number in addition to the code used for entry.
Example:
• Accessware applications software must be
used for programming with M802 & M805
controller.
• The Master Code is always User Location
“01”. The Master Code assigns the Emergency
and Supervisory Codes. It is also used for
programming. Users are deleted through the
Master Programming Code only.
• The Supervisory Code is User Location “03” for
M800 and “02” for M801-M806 Technology.
The Supervisory Code allows temporary lock
out of selected users, changes duration of
unlock time, requests infrared interrogation
output, and may add additional User Codes.
• The Emergency Code is User Location “02”
for M800 and can be assigned to locations
“03-2000” for M801-M806 Technology. The
Emergency Code cannot be locked out or
disabled. Presentation of a valid credential
by this user type will override any locked
condition and will unlock the door, including
User Lockout and Panic Lockdown states.
Presentation of this user type also allows entry
on a Access 800™ mortise controller if the
deadbolt is thrown. This user type will unlock
the door for the time specified in the Door
Settings screen under “Lock Timer - Extended
Users”.
• The User Codes are entered at user location
“04” or higher for M800 and “03” or higher for
M801-M806. User locations do not have to
be used or entered sequentially.
• The “Lock Out” user is location dependent
and will lock out all users beyond this location.
To ensure that all users are locked out of the
keypad, program this user at location “04” for
M800 and “03 for M801-M806.
• The “Passage” user has precedence over all
users except the “Panic” user. The lock must
be toggled back into a locked state for other
users to function.
• Remote Unlocking used for remote unlocking
of Access 800 lock. For the Mortise Lock,
when the deadbolt is thrown and the remote
unlocking feature is used, both the latchbolt
and deadbolt can be retracted by turning the
lever handle.
User Type
User Location
Master
Supervisor
Emergency
01
03 (M800), 02 (M801-M806)
02 (M800), 03-2000 (M801-M806)
Standard
04-100 (M800), 03-2000 (M801-M806)
1
3
2
5
4
TOC
Table of Contents
6
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
General Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Individual Door Log Sheet for Keypad Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
M800 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
M801, M803, M804, M806 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Chain Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
M802 and M805 Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7