background image

15

(617417440)

 

FM359 7/19

Access 800

™ 

Series

Locks

Keypad Programming Instructions

For installation assistance contact Corbin Russwin 

1-800-543-3658 • [email protected]

Copyright © 2018

-2019

 Corbin Russwin, Inc., an ASSA ABLOY Group 

company.  All rights reserved. Reproduction in whole or in part without the 

express written permission of Corbin Russwin, Inc. is prohibited.

7

M802 and M805 Programming

In a Prox Only M802 or RF Technology & Prox M805 configuration, all programming must be completed 
using AccesswareTM Software. The Software includes a convenient Software User’s Manual in .pdf 
format to be used as a programming guide. After setting up your system using the software, Hotsync to 
the PDA. Be sure to program a “Communications Enable” credential for future programming.
To program the lock for the first time or after memory is reset, the following steps are required. 
1. Use AccesswareTM software to set up your system and Hotsync door information to PDA.
2. Remove Battery Cover from inside of lock.
3. On PDA - select “Access HH”, then “Imp/Exp”

PDA Response: “Please enter your 

“Do 

NOT

 click OK at this point”

communications code at the door”

4. “Wake up” the M802 or M805 lock by presenting

any HID Prox Credential or by depressing an RF FOB   Lock Response: Audible beep

5. Within a couple seconds press and hold the controller CommEnable push button (white button

located in the battery compartment) for 2 seconds, then release the button.

6. On the PDA, click “OK”

The PDA will begin transferring (0-100%) of 
the door data to the lock.

If there was an error, check connections and repeat process starting at Step 3.

Note: The Credential will NOT actuate the lock for 45 seconds from the start of the downloading 
process. After this time expires, the Credential will function as defined by its User Type. 

Reprogramming
Note: Using the proximity card, FOB, tag or RF FOB programmed as a “CommEnable” User, 
present the “CommEnable” credential to the lock to initiate communications after performing 
Step 3 (above) without the need to press the CommEnable button.

Summary of Contents for Access 800

Page 1: ...inrusswin assaabloy com Copyright 2018 2019 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin...

Page 2: ...al by this user type will override any locked condition and will unlock the door including User Lockout and Panic Lockdown states Presentation of this user type also allows entry on a Access 800 morti...

Page 3: ...l times until the yellow LED goes out If no keystroke is made in a 30 second time frame the programming up to that point will default and you will have to start over Lock Model _______________________...

Page 4: ...r the Emergency Code 99 Master Code Yellow LED blinks 50 02 Yellow LED blinks Emergency 1 6 digits Yellow LED blinks quickly Emergency 1 6 digits Yellow LED blinks slowly Yellow LED goes out Emergency...

Page 5: ...blinks 56 0 Enable User Location 04 100 or 1 Disable User Location 04 100 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Delete A User 99 Master Code Yell...

Page 6: ...or or Master Code Yellow LED blinks 70 0 0 Yellow LED blinks Yellow LED blinks quickly Yellow LED goes out When printing finishes the green LED will turn off and the yellow LED will blink slowly Yello...

Page 7: ...owly Yellow LED goes out To Clear the Entire Memory and restore Factory default settings 99 Master Code Yellow LED blinks 46 00000 00000 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks r...

Page 8: ...2 Yellow LED blinks Supervisory 1 6 digits Yellow LED blinks quickly Supervisory 1 6 digits Yellow LED blinks slowly Yellow LED goes out Enter A User Code 99 Master Code or Supervisor Code Yellow LED...

Page 9: ...a Lock Out User Code 99 Master Code or Supervisor Code Yellow LED blinks 50 3 User Location 03 2000 Yellow LED blinks User Code Yellow LED blinks quickly User Code Yellow LED blinks slowly Yellow LED...

Page 10: ...enabled and this procedure does not have to be completed With the RF FOB function enabled the battery life of the unit will be reduced Press the white reset button located in the battery compartment...

Page 11: ...owly Yellow LED goes out User Type Table Note 1 There is a time delay period between initially depressing the RF FOB button and the actuation of the lock In some cases the RF FOB will have to be depre...

Page 12: ...Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out 24Hr Format 1PM 13 00 2PM 14 00 10PM 22 00 Midnight 00 00 1 15PM 13 15 Daylight Savings Time 99 Master Code Yel...

Page 13: ...ED blinks 50 0 User Number 03 2000 Yellow LED blinks Yellow LED blinks quickly Yellow LED blinks slowly Yellow LED goes out To Clear the Entire Memory 99 Master Code Yellow LED blinks 46 00000 00000 Y...

Page 14: ...er Code 2 to 6 digits which correlates with the User Location 99 Master or Supervisor Code 50 Type User Location a User Code a User Code a Type User Location b User Code b User Code b T ULc UCc UCc T...

Page 15: ...t up your system and Hotsync door information to PDA 2 Remove Battery Cover from inside of lock 3 On PDA select Access HH then Imp Exp PDA Response Please enter your Do NOT click OK at this point comm...

Page 16: ...019 Corbin Russwin Inc an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Corbin Russwin Inc is prohibited Patent pending and or...

Reviews: