Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
73
3.15: Hall Switch Inputs
XEL/XPL/XML
Channels
3 (U, V and W)
Type
74HC14 Schmitt trigger w/ RC Filter
10 k
pull-up resistor to in5 Vdc
Input Voltage Range
0 Vdc - +24 Vdc
Low Level Input Voltage
< +1.35 Vdc
High Level Input Voltage
> +3.65 Vdc
Timing
Edge detection.
RC Filter Time Constant
1
s when driven by active sources.
Function
Commutation of brushless motors in trapezoidal mode.
Commutation initialization and phase error detection in sinusoidal mode.
XE2/XP2/XM2/800-1818
Channels
6 (U, V and W for each axis)
Type
74HC14 Schmitt trigger w/ RC Filter
10 k
pull-up resistor to in5 Vdc
Input Voltage Range
0 Vdc - +24 Vdc
Low Level Input Voltage
< +1.35 Vdc
High Level Input Voltage
> +3.65 Vdc
Timing
Edge detection.
RC Filter Time Constant
1
s when driven by active sources.
Function
Commutation of brushless motors in trapezoidal mode.
Commutation initialization and phase error detection in sinusoidal mode.
NOTE: Digital Halls are not supported 800-1819 and 800-1887 drives.
Summary of Contents for XEL-230-18
Page 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Page 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Page 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Page 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...