4.3: Motor(s)
4.3.1: (J2) XEL/XPL/XML
Mating Connector
Description
Euro-style, 4 position, 5.0 mm pluggable female terminal block
Manufacturer PN
Wago: 721-104/026-047
Wire Size
22 - 12 AWG
Recommended Wire
18 A models: 14 AWG, 600 V
20 A, 36 A and 40 A models: 12 AWG, 600 V
Shielded cable required for CE compliance
Wire Insertion/Extraction Tool
Wago: 231-131
Standard connector and tool are included in Connector Kits XEL-CK, XML-CK, and XPL-CK.
Pin Description
Pin
Signal
Function
1
Ground
Motor frame ground and cable shield
2
W
Phase W output of drive
3
V
Phase V output of drive (use for DC motor connection)
4
U
Phase U output of drive (use for DC motor connection)