![Copley Controls XEL-230-18 User Manual Download Page 66](http://html1.mh-extra.com/html/copley-controls/xel-230-18/xel-230-18_user-manual_2666128066.webp)
Xenus Plus User Guide
16-01344 Rev 06
Copley Controls
66
3.3: Power Output
Model
XEL-230-18 (-R)*
XPL-230-18 (-R)*
XML-230-18 (-R)*
XEL-230-36 (-R)*
XPL-230-36 (-R)*
XML-230-36 (-R)*
XEL-230-40 (-R)*
XPL-230-40 (-R)*
XML-230-40 (-R)*
XE2-230-20 (-R,-N*)
XP2-230-20 (-R,-N*)
XM2-230-20 (-R,-N*)
800-1819
800-1887*
800-1818
Peak Current
18 Adc
[12.7 Arms]
36 Adc
[25.5 Arms]
40 Adc
[28.3 Arms]
20 Adc
[14 Arms]
9 Adc
[6.36
Arms]
Peak Current
Time
1 Second
Continuous
Current
6 Adc
[4.24 Arms]
12 Adc
[8.5 Arms]
20 Adc
[14.1 Arms]
10 Adc
[7 Arms]
4.5 Adc
[3.18
Arms]
Efficiency
>97% @ 230 Vac and rated continuous current
Output Type
3-phase IGBT inverter
16 kHz center-weighted PWM
space-vector modulation
PWM Ripple
Frequency
32 kHz
Minimum Load
Inductance
400 uH line-to-line**
NOTE: See
Xenus Plus Filter (p. 148)
Capacitor
Discharge
Wait 5 minutes after disconnecting mains power before handling
* Heat sinking and/or forced air cooling required for continuous output power rating
** Consult factory for operation with inductance lower than 400 uH
Summary of Contents for XEL-230-18
Page 1: ...123123 P N 16 01344 Revision 06 August 30 2019 Xenus Plus User Guide...
Page 2: ...Xenus Plus User Guide 16 01344 Rev 06 This page for notes...
Page 9: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 9 This page for notes...
Page 18: ...Xenus Plus User Guide 16 01344 Rev 06 Copley Controls 18...