68
USER'S MANUAL
Installation for outdoor unit
Dimension drawing of outdoor unit installation
Install the connection pipe
Connect the Outdoor Unit with Connecting Pipe : Aim the
counter-bore of the connecting pipe at the stop valve, and
tighten the Taper nut with fingers. Then tighten the Taper
nut with a torque wrench.
•
When prolonging the piping, extra amount of
refrigerant must be added so that the operation and
performance of the air conditioner will not be compromised
Note :
1.
This table is for reference only.
2.
The joints shall not be reused, unless after re-flaring the pipe.
3.
After installation, check the stop valve cover whether be fixed
effectively.
50
cm. Abo
ve
Space to the obstruction
10
cm. Above
Air in side
30 cm. Above
Space to the obstruction
20 cm. Above
Air out side
50 cm. Above
Space to the obstruction
665 (710 )×420×280
430
280
A (mm )
B ( mm )
600 (645 )×485×260
400
290
660 (710 )×500×240
500
260
700 (745 )×500×255
460
260
730 (780 )×545×285
540
280
760 (810 )×545×285
540
280
800 (860 )×545×315
545
315
800 (850 )×590 (690 )×310
540
325
825 (880 )×655×310
540
335
900 (950 )×700×350
630
350
900 (950 )×795×330
535
350
790 (840 )×550×290
545
300
970 (1044 )×803×395
675
409
Stop valve Taper nut
Liquid
side pipe
Gas
side pipe
Spanner
Stop
valve
cover
Connection
pipe
≤5M
CC≤12000Btu
16g/m
≤1kg
≤2kg
24g/m
CC≥18000Btu
5-15M
Not needed
Amount of refrigerant to be added
Piping length
Amount of
refrigerant for
the unit
Outdoor Unit Size of Shape
W1(W2)*H*D) (mm)
A
H
W1
B
D
W2
Air outlet
Air inlet
Left installation feet
Right installation feet
Installation outdoor unit bolt