67
USER'S MANUAL
Installation for indoor unit
Connect interconnection cord of indoor unit
1.
Open the panel, remove the screw on the wiring
cover and then take down the cover.
2.
Make the interconnection cord go through the
cable-cross hole at the back of indoor unit and
then pull it out from the front side.
(Some models do not have a signal cable.)
After installation check
1.
The screws whether have been fixed effectively, and there is no risk of loosening.
2.
Connector of display board whether put in the right place and do not touch the
3.
Control box cover whether cover tightly
Not :
BThis manual usually includes the wiring mode for the different kind of air
conditioner. We cannot exclude the possibility that some special type of wiring
diagrams are not included.
The diagram are for reference only. If the entity is difference with this wiring diagram,
please refer to the detailed wiring diagram adhered on the unit which you purchased
3.
Remove the wire clip; connect the interconnection cord to the wiring terminal
according to the wiring diagram; tighten the screw and then fix the interconnection
cord with wire clip.
4.
Put wiring cover back and then tighten the
screw.
5.
Close the panel.
Interconnection cord installation
Lo
N
S
L
L
N
S
4
1(L)
5
3
2(N)
1(L)
2(N)
4
5
3
Panel
Screw
Panel
Screw
Wiring cover
If there is a connector,
connect it directly.
Connector
To Outdoor unit
To Outdoor unit
To Outdoor unit
To Outdoor unit
Constant Speed
Variable Speed
Signal cable
Interconnection
cord