Elpro Technologies 450U-E Wireless Ethernet Modem & Device Server User Manual
26
www.cooperbussmann.com/wirelessresources
Rev Version 1.0.12-Beta7
Default Gateway - This is the address that the device will use to forward messages to remote hosts that
are not connected to any of the local bridged network (Ethernet or Wireless). This is only required if the
wired LAN has a Gateway unit which connects to devices beyond the LAN - for example, Internet
access. If there is no Gateway on the LAN, set to the same address as the Access Point - that is, the
r more information.
2.
Save Changes and Reset
General Configuration
3.5
Connecting to Existing Networks.
When configured as a Bridge (default), the 450U-E will transmit all broadcast messages appearing at its wired Ethernet
port over the radio. As the modem has a low data throughput any unnecessary traffic being sent over the radio could
lower the available bandwidth which will compromise the reliability of the wireless link.
In many cases, the intended recipient of the broadcast traffic that is heard on the Ethernet port does not lie at the
opposite end of a proposed radio link. Therefore it is recommended that the radios be configured with some basic filtering
or be configured as a routing network to limit unnecessary broadcast traffic being sent over the radio. Refer to Section
3.14 Filtering
this can be implemented.
A system of 450U-E
All 450U-E
d Radio Encryption settings. For further information
and examples on wireless network topologies refer section 1.0 Network Topology
The 450U-E supports three different radio encryption methods, WEP128, WPA2-PSK and WPA Enterprise which can be
configured on the Security Page. The default encryption method is WPA2 and is setup during the Quickstart process by
simply entering a Password.
If utilising any form of encryption, all modules in the system will need the same encryption method and keys. It is advisable
to enter a new password and to not use the
The available encryption methods are described in
detail in Section 3.8 Security Menu below.
Note: If making changes to a remote module via the radio link make sure all changes are compliant and accurate
before
Changes and R
and will require a hard wire connection to change back.
You can view or modify any of the webpage configuration parameters by selecting the appropriate link from the right hand
menu. Wh
user
user
the factory default See section 4.10 Module Information Configuration
If you have forgotten the IP address or password, the Factory Default switch may be used to access the existing
configuration. Refer to Default Configuration
3.2 above for this procedure.