Page 

Option  

Disabled. The display shows alert messages for faults, but does not 
sound alert tones.  

Enabled (default). The display shows alert messages, and the system 
gives alert tones. 

Command 151 to 158: Plug-by Communicator Outputs 

1. Note that All Fault is active for the following faults: AC Fail, Anti-Mask, Aux 

DC, Battery Load Test Fail, Battery Missing, Comms Fail, Jamming, 
Keypad Ident Fail, Line Fail (internal communicator only), Low Battery, RF 
Low Battery, Supervision Fail, Telecommand Low Battery, uCom Fail, 
Zone AC Fail, Zone Battery Fault, Zone Fault, Zone Low Battery and Zone 
Pwr O/P. (Plug-By/Plug-On fail no longer trigger an All Fault output.) 

2. In the event of a mains fail (or if the installer leaves engineering with mains 

absent) the control unit waits one minute and then logs an AC Alert, but 
does not start any communication. If the mains fail persists, then after a 
time of 15-19 min (chosen at random) the control unit logs an AC Fail and 
also starts a communication.  
If you select a Scandinavian default in Command 0, the control unit waits at 
least 60 minutes before reporting. 

Printing the Event Log (9853 only) 

The following log messages are new in version 5.0x.: 

Keypad Display 

Printed (9853 only)* 

Meaning 

AC Alert 

 

Keypad displayed mains fail message 

AC Fail 

AC Lost 

Mains power supply failed 

Z== Lock Out 

 

The system locked out the zone when 
attempting to rearm at the end of the bell 
run time. 

Z== Lock Out Rst 

 

The system restored a locked out zone 
zone. 

4. Changes For the End User 

Access Codes 

With version 5 access codes can have “0” as the first digit.  
The end user no longer has to press 

X

 to cancel a mistake in entering an 

access code, they simply key in the correct code again.  
If a user keys in an incorrect code four times, the control unit locks all keypads 
for 90 seconds. 

Summary of Contents for Scantronic 9751

Page 1: ...9x5x VERSION 5 UPDATE GUIDE HARDWIRED CONTROL UNITS...

Page 2: ...nly 7 4 Changes For the End User 7 Access Codes 7 Downloader Calling Control Unit 8 9853 9752 9751 Version 5 Update Guide This document applies to control panels using software version 5 x x Cooper Se...

Page 3: ...Installer Programming Leading 0 Now Allowed in Access Codes All access codes both user and installer four digit and six digit can have 0 as the first digit Entering and Leaving Installer Mode When you...

Page 4: ...will still report faults on a plug by communicator provided the Line Fault output from the communicator are connected to the control unit Command 131 Various new reports have been added to command 13...

Page 5: ...SYSTEM TAMPER RESTORE TR 137 TA Technical alarm UA 150 TA RESTORE UR 150 TAMPER KEYPAD TA 137 TAMPER KEYPAD RESTORE TR TELCO1 FAULT LT 351 TELCO1 FAULT RESTORE LR ZONE OMIT BB 573 ZONE TAMPER TA 137 Z...

Page 6: ...ET JT 625 TX BATTERY TROUBLE XT 384 USER CODE CHANGED JV USER CODE DELETED JX Notes 1 If Command 143 option 1 is selected all messages with a CID Code are sent If option 0 is selected the restores mar...

Page 7: ...Alert but does not start any communication If the mains fail persists then after a time of 15 19 min chosen at random the control unit logs an AC Fail and also starts a communication If you select a S...

Page 8: ...The display shows Call CS 3 Presses B and then y The display shows Remote PC _ In Progress The Installer s PC can then attempt to call the control unit over the telephone line While Downloader is con...

Reviews: