background image

 

Page 6 

LOW BATT RESTORE (see note 6) 

YR 

311‡ 

PARTITION RESET 

OR 

305 

RESET OR 

305 

INTERMEDIATE  

 

Event SIA 

Code 

CID 

Code 

ARM CL 

401 

DISARM OP 

401 

KEYSWITCH DISARM 

OS 

409 

KEYSWITCH ARM 

CS 

409 

ZONE FAULT 

IA 

389 

ZONE FAULT RESTORE 

IR 

389 

FULL  

 

Event SIA 

Code 

CID 

Code 

COMMS FAIL 

350 

DOWNLOAD SUCCESS 

RS 

412 

EXCESS KEYS 

JA 

461 

EXPANDER MISSING 

TA 

137 

EXPANDER MISSING RESTORE 

TR 

137‡ 

FORBI MISSING 

TA 

137 

FORBI MISSING RESTORE 

TR 

137‡ 

JAMMING XQ 

380 

PASSWORD DEFAULTS LOADED 

RH 

PROG MODE START 

LB 

627 

PROG MODE END 

LS 

628 

TD (Time and day) RESET 

JT 

625 

TX BATTERY TROUBLE 

XT 

384 

USER CODE CHANGED 

JV 

USER CODE DELETED 

JX 

Notes: 
1. 

If Command 143, option 1 is selected, all messages with a CID Code are sent. If 
option 0 is selected, the restores marked with ‡ are not sent. 

2. 

This message also sent for PAs started from a telecommand. 

3. 

The control unit logs an Anti-Mask event to the zone number one below that assigned 
the Anti-Mask type. 

4. 

This message also sent for Power zones. 

5. 

This message also sent for Battery Fault zones. 

6. 

This message also sent for Low Battery zones. 

Command 141: Alert Tone On/Off 

This is a new command in version 5.0x. Use this command to disable the 
Alert fault tones. When enabled (default) the system gives an alert tone and 
displays alerts on the keypad. 

Summary of Contents for Scantronic 9751

Page 1: ...9x5x VERSION 5 UPDATE GUIDE HARDWIRED CONTROL UNITS...

Page 2: ...nly 7 4 Changes For the End User 7 Access Codes 7 Downloader Calling Control Unit 8 9853 9752 9751 Version 5 Update Guide This document applies to control panels using software version 5 x x Cooper Se...

Page 3: ...Installer Programming Leading 0 Now Allowed in Access Codes All access codes both user and installer four digit and six digit can have 0 as the first digit Entering and Leaving Installer Mode When you...

Page 4: ...will still report faults on a plug by communicator provided the Line Fault output from the communicator are connected to the control unit Command 131 Various new reports have been added to command 13...

Page 5: ...SYSTEM TAMPER RESTORE TR 137 TA Technical alarm UA 150 TA RESTORE UR 150 TAMPER KEYPAD TA 137 TAMPER KEYPAD RESTORE TR TELCO1 FAULT LT 351 TELCO1 FAULT RESTORE LR ZONE OMIT BB 573 ZONE TAMPER TA 137 Z...

Page 6: ...ET JT 625 TX BATTERY TROUBLE XT 384 USER CODE CHANGED JV USER CODE DELETED JX Notes 1 If Command 143 option 1 is selected all messages with a CID Code are sent If option 0 is selected the restores mar...

Page 7: ...Alert but does not start any communication If the mains fail persists then after a time of 15 19 min chosen at random the control unit logs an AC Fail and also starts a communication If you select a S...

Page 8: ...The display shows Call CS 3 Presses B and then y The display shows Remote PC _ In Progress The Installer s PC can then attempt to call the control unit over the telephone line While Downloader is con...

Reviews: