background image

 

  

Page 

KEYPAD MEDICAL 

MA 

100 

KEYPAD FIRE 

FA 

110 

KEYPAD PA 

HA 

120 

LID TAMPER 

TA 

137 

LID TAMPER RESTORE 

TR 

137‡ 

MAN TRIGGER TEST REPORT 

RX 

601 

PANIC (see note 2) 

PA 

120 

PANIC RESTORE 

PR 

120‡ 

PERIODIC TEST REPORT 

RP 

602 

SENSOR SELF TEST FAILURE 

389 

SENSOR TAMPER 

TA 

137 

SENSOR TAMPER RESTORE 

TR 

137‡ 

SMOKE DETECTOR 

FA 

111 

SMOKE DETECTOR RESTORE 

FR 

111‡ 

BELL TAMPER 

TA 

137 

BELL TAMPER RESTORE 

TR 

137‡ 

SUPERVISION FAIL 

BZ 

381 

SYSTEM TAMPER 

TA 

137 

SYSTEM TAMPER RESTORE 

TR 

137‡ 

TA (Technical alarm) 

UA 

150 

TA RESTORE 

UR 

150‡ 

TAMPER KEYPAD 

TA 

137 

TAMPER KEYPAD RESTORE 

TR 

TELCO1 FAULT 

LT 

351 

TELCO1 FAULT RESTORE 

LR 

ZONE OMIT 

BB 

573 

ZONE TAMPER 

TA 

137 

ZONE TAMPER (DAY) 

TA 

ZONE TAMPER RESTORE 

TR 

137‡ 

SUMMARY  

 

Event SIA 

Code 

CID 

Code 

AC LOST 

AT 

301 

AC RESTORE 

AR 

301‡ 

ALARM ABORT 

BC 

406 

ANTI MASK ZONE OPEN (see note 3) 

BT 

380 

ANTI MASK ZONE TAMPER (see note 3) 

BT 

380 

ANTI MASK ZONE RESTORED (see note 3) 

BJ 

380 

AUX TROUBLE (see note 4) 

YP 

AUX RESTORE (see note 4) 

YQ 

BATT MISSING (see note 5) 

YM 

311 

BATT RESTORED (see note 5) 

YR 

311‡ 

FAULT ZONE 

TA 

300 

FAULT ZONE RESTORE 

TA 

300‡ 

LOW BATT (see note 6) 

YT 

311 

Summary of Contents for Scantronic 9751

Page 1: ...9x5x VERSION 5 UPDATE GUIDE HARDWIRED CONTROL UNITS...

Page 2: ...nly 7 4 Changes For the End User 7 Access Codes 7 Downloader Calling Control Unit 8 9853 9752 9751 Version 5 Update Guide This document applies to control panels using software version 5 x x Cooper Se...

Page 3: ...Installer Programming Leading 0 Now Allowed in Access Codes All access codes both user and installer four digit and six digit can have 0 as the first digit Entering and Leaving Installer Mode When you...

Page 4: ...will still report faults on a plug by communicator provided the Line Fault output from the communicator are connected to the control unit Command 131 Various new reports have been added to command 13...

Page 5: ...SYSTEM TAMPER RESTORE TR 137 TA Technical alarm UA 150 TA RESTORE UR 150 TAMPER KEYPAD TA 137 TAMPER KEYPAD RESTORE TR TELCO1 FAULT LT 351 TELCO1 FAULT RESTORE LR ZONE OMIT BB 573 ZONE TAMPER TA 137 Z...

Page 6: ...ET JT 625 TX BATTERY TROUBLE XT 384 USER CODE CHANGED JV USER CODE DELETED JX Notes 1 If Command 143 option 1 is selected all messages with a CID Code are sent If option 0 is selected the restores mar...

Page 7: ...Alert but does not start any communication If the mains fail persists then after a time of 15 19 min chosen at random the control unit logs an AC Fail and also starts a communication If you select a S...

Page 8: ...The display shows Call CS 3 Presses B and then y The display shows Remote PC _ In Progress The Installer s PC can then attempt to call the control unit over the telephone line While Downloader is con...

Reviews: