background image

21

WARRANTY NOTICE

Cooke Industries will provide a new or repaired part or component at its discretion in place 

of any part or component, which is found upon inspection, to be defective in material or 

workmanship during the warranty period.

Said part or component will be repaired or replaced without charge to the initial user  

during normal working hours at the place of business of Cooke Industries or a Cooke 

Industries nominated distributor upon the consent of Cooke Industries.

This warranty does not apply to failure occurring as a result of abuse, misuse, negligent 

installation or repair and/or alterations or modifications whatsoever made to the  

product without the express written consent of Cooke Industries. This also extends to 

outside influences or site conditions which may impede or obstruct the correct functioning 

of the unit.

Warranty claims are to be lodged at 

www.cookeindustries.com.au/warranty

Please note the user must submit the serial number and proof of purchase to make a claim 

under this warranty.

SPECIAL CONDITIONS

1.

  Onsite labour, service call or freight charges to return items to Cooke Industries are the 

responsibility of the purchaser.

2.

  Under no circumstances whatsoever shall Cooke Industries be liable for incidental or 

consequential damages, inconveniences or expenses in connection with the removal or 

replacement of this product.

3.

  In circumstances whereby it has been deemed that the installer has clearly not followed 

the steps and information as set out in this guide (negligent installation), the warranty 

will become null and void.

4.

  Under no circumstances will Cooke Industries be liable for damage caused to persons 

or property as a result of the incorrect installation or misuse of this product.

Summary of Contents for WaterWitch

Page 1: ...Product Support Guide Full Electrical Certi cation Inside Outside use ESV160204 C Tick Approval N11116...

Page 2: ...pes were developed and tested in my shed at home until we had a suitable production model After a few years of production further tweaks and improvements were decided upon The Water Witch was born For...

Page 3: ...x installation Page 05 Sensor installation Page 06 Solenoid installation Page 08 Alternative installation options Page 10 Start up process Page 12 Test and time delay modes Page 13 Operation of indica...

Page 4: ...and must be returned upon its request Template updated August 2014 WaterMark Certificate Of Conformity Level 1 This is to certify that Nymet Australia Pty Ltd ABN Head Office Address 1 53 Stanbel Road...

Page 5: ...ficient overflow provisions to avoid a potential flooding event The Water Witch may not be suitable for installations where the water source is connected to a pressure pump Confirm high and low pressu...

Page 6: ...ONTROL BOX WS345 Water Witch Control Box SENSOR WS355 Water Witch Sensor Only 5m WS356 Water Witch Sensor Only 20m WS357 Water Witch Sensor Only 30m WS358 Water Witch Sensor Only 40m WS359 Water Witch...

Page 7: ...least 1 2m above ground level and ensure a consistent power source is within reach of the Control Box power lead The Control Box is approved for indoor and outdoor use However locating the Control Box...

Page 8: ...the Sensor As the ball intersects the light beam at the top of the Sensor the Control Box recognises the full water level Instead of stopping the flow immediately the TIME DELAY MODE then overfills th...

Page 9: ...suction and return trench and elbowed up within the equipment area THESE PIPES MUST BE LEVEL TO AVOID AIR LOCKS which will affect flow and performance A 50mm cap is provided to cover the sensor pipe h...

Page 10: ...r INSTALLATION PROCESS AND CONSIDERATIONS The Solenoid flow is one directional ENSURE THE SOLENOID FLOW DIRECTIONAL ARROW IS POINTED IN THE SAME DIRECTION AS THE WATER FLOW The Solenoid has a 20mm mal...

Page 11: ...a hard connection An air gap is required to ensure the water from the project cannot contaminate the water source THE FILL FLOW RATE MUST NOT EXCEED THE RATE THE BALNCE LINE TRANSFERS WATER INTO THE P...

Page 12: ...he Sensor end cap Run the Sensor cable through appropriately sized conduit to ensure the Sensor can be accessed for serviceability and replaced if required Small debris capable of affecting sensor per...

Page 13: ...kely result in severe pump equipment and site damage The water level in the trough may increase dramatically during a significant rainfall event or heavy bather load The trough capacity above the mini...

Page 14: ...ate full water level The ON and SENSE lights should flash in unison every 2 4 seconds STEP 5 Turn the Sensor around the right way up to simulate low water level The ON light should continue to flash e...

Page 15: ...L cycle The four time delay settings are controlled by the position of dip switches inside the bottom right corner of the Control Box STEP 8 TURN THE POWER SUPPLY OFF AND UNPLUG THE WATER WITCH POWER...

Page 16: ...t the correct height ON light is flashing every 2 4 seconds and the FILL light is solid The Water Witch is in TEST MODE and is adding water because it believes the water level is low ON and FILL light...

Page 17: ...following tables to identify the fault being experienced and the action required to remedy the fault WATER WILL NOT TURN ON Light Display Possible Fault Remedy ON SENSE Sensor debris may be impeding f...

Page 18: ...he flow directional arrow on the Solenoid is pointing in the same direction as supply flow Reinstall if required Solenoid wire is damaged or does not have a positive connection to control box Ensure t...

Page 19: ...most likely too high Water pressure is too high Install a Pressure Limiting Valve between supply tap Solenoid to reduce pressure WATER WILL NOT TURN OFF Be aware there is a tiny spring and rod inside...

Page 20: ...plate from bottom of Sensor Remove ball to clean the inside of Sensor Sensor or Control Box has failed Return Control Box to Test Mode and complete the following to confirm fault Hold Sensor in uprig...

Page 21: ...are corroded damaged or blown There are markings caused by water ingress You will most likely need to replace the Control Box if you are experiencing any of the above faults If the Control Box housin...

Page 22: ...trol Box as required Annually Remove the solenoid pre filter to clear any debris or contaminant Maintenance checks should be conducted more regularly for commercial applications Product Water Witch El...

Page 23: ...ditions which may impede or obstruct the correct functioning of the unit Warranty claims are to be lodged at www cookeindustries com au warranty Please note the user must submit the serial number and...

Page 24: ...Cooke Industries P 1300 652 076 E info cookeindustries com au cookeindustries com au...

Reviews: