13
Mode
Description
CAPACITY
(LITRES)
SWITCH
1
SWITCH
2
SWITCH
3
SWITCH
4
ADDITIONAL
FLOW
Test Mode
N/A
UP
UP
UP
UP
2 Seconds
Spa
Up to 10,000
UP
DOWN
UP
UP
13 Seconds
Pool
10,000-50,000
UP
UP
DOWN
UP
75 Seconds
Commercial
More than 50,000
UP
UP
UP
DOWN
330 Seconds
TEST AND TIME DELAY MODES
The Water Witch features four time delay settings
that control the length of the FILL cycle. The time
delay slightly fills the pool with additional water to
prevent the Water Witch from continually engaging
and disengaging the FILL cycle. The four time delay
settings are controlled by the position of dip switches
inside the bottom right corner of the Control Box.
STEP 8:
TURN THE POWER SUPPLY OFF AND UNPLUG THE
WATER WITCH POWER LEAD.
STEP 9:
Remove the Water Witch Control Box cover and set the Dip Switches to
the correct mode as per the table above.
STEP 10:
Replace the Water Witch Control Box cover, plug in the power lead and
turn the power on.
THE WATER WITCH IS NOW SET TO THE CORRECT WATER LEVEL AND TIME
DELAY MODE.
Refer to the following table for the appropriate time delay setting for your project:
If you need to test the Water Witch or any of its
components you must always return the unit to
TEST MODE as per the correct dip switch setting.