16
TROUBLESHOOTING PROCESS
(CONTINUED)
WATER WILL NOT TURN ON:
Light Display
Possible Fault
Remedy
ON & FILL
Water supply is not turned on
Turn water supply on
Water pressure is too high
Install a Pressure Limiting Valve
between supply tap & Solenoid
to reduce pressure
Solenoid has been installed
backwards
Ensure the flow directional
arrow on the Solenoid is
pointing in the same direction as
supply flow. Reinstall if required
Solenoid wire is damaged
or does not have a positive
connection to control box
Ensure there is a solid
connection for electrical current.
A multimeter should record 22V
DC at the end of the solenoid
cable and 7-9V DC whilst the
Solenoid is drawing power
Water pressure is too low
Supply pressure must be
29-116 PSI (200-800 kPa)
Solenoid may need to be replaced if these actions do not correct
fault