• The solenoid requires an operating pressure range of 29-116 PSI (200-800 kPa).
ENSURE THE ONSITE PRESSURE IS SUITABLE FOR CORRECT OPERATION OF
THE SOLENOID.
Install a pressure limiting valve on the water supply line if the onsite
pressure is greater than 116 PSI (800 kPa).
•
A TAP OR TWO-WAY VALVE MUST BE
PLACED BEFORE THE SOLENOID TO
ENABLE THE WATER SOURCE TO BE
TURNED OFF AT ANY TIME.
• Standard installation positions the supply line
20mm above the fill balance line without a hard
connection (An air gap is required to ensure the
water from the project cannot contaminate the
water source).
THE FILL FLOW RATE MUST
NOT EXCEED THE RATE THE BALNCE LINE
TRANSFERS WATER INTO THE PROJECT.
• If approved in your local area, the fill line can
be plumbed into the filtration return line.
If installing in this manner,
A BACKFLOW
PREVENTER MUST BE INSTALLED
BETWEEN THE SOLENOID AND THE
WATER SOURCE TAP.
•
INSERT THE SOLENOID PLUG
INTO THE CORRECT PORT
ON THE CONTROL BOX AS
INDICATED ON THE LABEL.
20mm
The solenoid is a wearing
component with an indefinite
operating life. Your project
should include suitable overflow
provision in case of possible
solenoid failure.