VISUALIZATION OF THE THREE PHASE VALUES 

 

VISUALIZATION OF THE SINGLE PHASE VALUES 

(connection mode set to 

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 1

VL-N  on L1

IL       on L2
kW     on L3

Visualization page 4

Three Phase Active Energy
counted 
232,8 kWhr

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 2

PF     

L1

on 

kVAr  on L2
kVA    on L3

Visualization page 5

Three Phase Reactive Energy
counted 
82,8 kVArhr

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 3

VL-L   on L1

Freq.  on L2

Visualization page 6

Three Phase Apparent Energy
counted 
520237.9 kVAhr

L

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

L1

L2

L3

EMM-µD3  

electrical multi meter

Visualization page 7

Three Phase 
Hour counter
520.2 h

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 1

VL1-N 

 L1

 

 on

IL1        on L2
kWL1    on L3

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 4

Active Energy counted

phase 

232,8 kWhr

L1 

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 2

PFL1     

L1

 on 

kVArL1    on L2
kVAL1     on L3

 

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 3
for EMM-µD3h-p

Freq. phase L1
Digital Output 1 Status on L2
Digital Output 1 Status on L3

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 5

Reactive Energy  counted 
L1 phase
82,8 kVArhr

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 6

Apparent 
L1 

Energy counted

phase 

520237.9 kVAhr

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 7

Hour counter L1 phase

00520.2 h

L1

L2

L3

L

EMM-µD3  

electrical multi meter

V

L-N

A

kW

kVAr

kVA

V

L-L

...h

Hz/

out

max

avg

SET

P.F.

Visualization page 3
for EMM-µD3h-485

Freq. phase L1
Address                    on L2
Transmission status on L3

Summary of Contents for EMM-mD3h

Page 1: ...ard version 110V rated 50 60Hz optional version 400V rated 50 60Hz optional version INTRODUCTION The EMM D3h are only featured for local visualising the electrical parameters The EMM D3h p has two dig...

Page 2: ...he terminals aux1 and aux2 The rated supply voltages can be standard Vn 230V 15 50 60Hz under request Vn 110V 15 50 60Hz under request Vn 400V 15 50 60Hz measuring voltage inputs 4 terminals are avail...

Page 3: ...PHASE LINE WITH 3 OR 4 WIRES EMM LOAD aux1 aux2 auxiliary supply VL1 VL2 VL3 N measur ing voltage inputs EMM aux1 aux2 auxiliary supply VL1 VL2 VL3 N measuring voltage inputs EMM aux1 aux2 auxiliary s...

Page 4: ...r wiring the voltage measures input and auxiliary supply F Terminals for wiring the current measures input and the digital output when present in the instrument G LED for indicating of a three phase v...

Page 5: ...or EMM D3h p kWh kVAr pulse Set pulse weight kWh kVAr pulse kWh kVAr pulse kWh kVAr pulse only for EMM D3h p Increase from to mS in step by 100 mS Decrease only for EMM D3h 485 Increase Set address of...

Page 6: ...e connection It s possible to chose 3 wires or 4 wires With the 4 wires connection the neutral parameter are displayed and enabled to use for the digital outputs settings Programming of the synchronis...

Page 7: ...arm In mode the digital output DO1 will emit pulses proportional to the active energy counted while the digital output DO2 will emit pulses proportional to the reactive energy counted The proportional...

Page 8: ...B key pressed to decrease the values The range depends by the parameter and it is linked to the CT and VT ratios Pressing A key to confirm The threshold set is linked with CT and VT ratios for this re...

Page 9: ...the energy meters are shown with the lighting of the LED kW h indicating the active energy values kWh whilst the lighting of the LED kVAr h are indicating the reactive energy values kVArh The lightin...

Page 10: ...lti meter Visualization page 7 Three Phase Hour counter 520 2 h L1 L2 L3 L EMM D3 electrical multi meter VL N A kW kVAr kVA VL L h Hz out max avg SET P F Visualization page 1 VL1 N L1 on IL1 on L2 kWL...

Page 11: ...max V L3 N max phase current I L1 max I L2 max I L3 max average phase current maximum demand I L1 max avg I L2 max avg I L3 max avg three phase system powers W max VAr max VA max average three phase s...