21

W415-0318 / 03.05.09

TERMINAL KITS

REF NO.

PART NO.

DESCRIPTION

34

GDI-226

TERMINAL KIT

VENT KITS

REF NO.

PART NO.

DESCRIPTION

1-2" & 1-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST & 2-3" TO 2" REDUCER:

35*

GDI-2320KT

VENT KIT 20FT

35*

GDI-2325KT

VENT KIT 25FT

35*

GDI-2335KT

VENT KIT 35FT

2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST:

36*

GDI-320KT

VENT KIT 20FT

36*

GDI-325KT

VENT KIT 25FT

36*

GDI-335KT

VENT KIT 35FT

 COMPONENTS

REF NO.

PART NO.

DESCRIPTION

23*

W290-0063

BLOWER ACCESS GASKET

24*

W430-0013

MAGNETIC CLOSURE

25*

W660-0009

ON/OFF SWITCH

26*

W690-0002

THERMAL DISC

27*

W380-0002

VARIABLE SPEED SWITCH KNOB

28*

W660-0019

VARIABLE SPEED SWITCH

29*

W450-0023

PAL NUT

30*

W730-0024

3" STAINLESS FLEX LINER X 3'

31*

W175-0204

3" COUPLER

32

W010-0888

VENT CONNECTION ASSEMBLY

33*

W290-0076

VENT CONNECTION ASSEMBLY GASKET

46ACCESSORIES46

REF NO.

PART NO.

DESCRIPTION

37*

W690-0001

MILLIVOLT THERMOSTAT

38*

W660-0010B

REMOTE CONTROL - ADVANTAGE

38*

W660-0011B

REMOTE CONTROL - ADVANTAGE PLUS

39*

GD660

REMOTE WALL SWITCH C/W 20FT WIRE

40

GI826KT

DECORATIVE BRICK PANELS

41*

W175-0202

NATURAL GAS TO PROPANE CONVERSION KIT

42

GDIBP3

3 SIDED BACKER PLATE C/W ACCENT TRIM

43

GDIBP4

4 SIDED BACKER PLATE C/W ACCENT TRIM

44

GDITRM3

ALUMINIUM EXTRUSION - MATTE BLACK 

44

GDITRM3-K

ALUMINIUM EXTRUSION - POLISHED BLACK

44

GDITRM3-B

ALUMINIUM EXTRUSION - POLISHED BRASS

45

GDITRM4

ALUMINIUM EXTRUSION - MATTE BLACK 

45

GDITRM4-K

ALUMINIUM EXTRUSION - POLISHED BLACK

45

GDITRM4-B

ALUMINIUM EXTRUSION - POLISHED BRASS

46

GDIUT

UPPER DOOR TRIM - BRASS

46

GDIUT-G

UPPER DOOR TRIM - GOLD

47

GDIBP3D

BACKER PLATE  3 SIDED DELUXE

Summary of Contents for CDI-44N

Page 1: ...tructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the supplier SAFETY INFORMATION CERTIFIED...

Page 2: ...NUM EXTRUSION TRIM KIT INSTALLATION 11 3 2 LOG PLACEMENT 12 3 3 GLOWING EMBERS 13 3 4 DOOR INSTALLATION 13 3 5 MINIMUM MANTEL CLEARANCE 14 4 0 OPERATION 15 4 1 REAR BURNER CONTROL 16 5 0 MAINTENANCE 1...

Page 3: ...ents burners and circulating blower and its passageway in the heater and venting system are kept clean The heater and its venting system should be inspected before use and at least annually by a quali...

Page 4: ...ers will nullify this warranty This limited warranty further does not cover any scratches dents corrosion or discoloring caused by excessive heat abrasive and chemical cleaners nor chipping on porcela...

Page 5: ...AUST 3 5 20 30 21 22 27 52 1 8 42 ALUMINUM TRIM 52 1 8 33 ALUMINUM TRIM 3 SIDED BACKER PLATE FRONT VIEW 4 SIDED BACKER PLATE FRONT VIEW TOP VIEW FIGURE 1 2a FIGURE 1 2b FIGURE 1 2c FIGURE 1 2e FIGURE...

Page 6: ...disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 psig 3 5 kPa The fireplace must be isolated from the gas supply piping syst...

Page 7: ...ace prefabricated or masonry only The minimum fireplace opening size in which the heater is to be installed is HEIGHT 21 inches WIDTH 32 inches DEPTH 16 inches The minimum allowable chimney flue size...

Page 8: ...chimney cleanouts fit properly The refractory glass doors screen rails screen mesh and log grates may be removed from the fireplace before installing the gas fireplace insert Smoke shelves shields and...

Page 9: ...and log support are detached by removing the 12 perimeter screws of the back wall and the 3 screws located at the back of the log support Remove the vent connection assembly NOTE The vent connection a...

Page 10: ...not bent or kinked Check for gas leaks by brushing on a soap and water solution For ease of accessibility an optional remote wall switch or millivolt thermostat may be installed in a convenient locat...

Page 11: ...If this unit is being installed into an existing wood burning zero clearance fireplace then be aware of this precaution Any circulation air opening may be covered with material but not sealed The inse...

Page 12: ...NG PIN LOCATING PIN B A C D The rear log should be centred on the log support and rest against the rear wall Log 3 rests against the far left grate post and onto the locating pin on the centre support...

Page 13: ...Use only certified glowing embers and PHAZERTM logs available from your Continental dealer FIGURE 3 4 1 3 4 1 Insert the tool supplied which is located behind the left side trim into spring loaded do...

Page 14: ...NIMUM MANTEL CLEARANCE This can vary according to the mantle depth Use the graph to help evaluate the clearance needed FIGURE 3 5b FIGURE 3 5a 0 4 14 3 5 H E I G H T M A N T E L MANTEL DEPTH 13 12 15...

Page 15: ...off all gas to the fireplace Open windows Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s...

Page 16: ...ory If ignition takes longer consult yourAuthorized dealer distributor 5 0 7 Check that the door gasketing is not broken or missing Replace if necessary The Continental gas fireplace insert comes stan...

Page 17: ...Reinstall the fire viewing door 6 0 7 Turn the gas supply and electricity back on Drywall dust will penetrate into the blower bearings causing irreparable damage and must be prevented from coming int...

Page 18: ...TTING 2 3 LINER SYSTEM FRONT REAR NG 1 8 1 4 LP 1 4 5 8 AIR SHUTTER SETTING This unit is approved for use with a 2 liner for air intake and a 3 liner for exhaust For best performance how ever it is re...

Page 19: ...ne Check that main burner is operating on HI Outlet pressure can be checked the same as above using screw B Gauge should read 3 5 water column for natural gas or 10 water column for propane Check that...

Page 20: ...age or personal injury This is a fast acting thermocouple It is an integral safety component Replace only with a fast acting thermocouple supplied by Wolf Steel Ltd WARNING COMPONENTS REF NO PART NO D...

Page 21: ...FLEX LINER X 3 31 W175 0204 3 COUPLER 32 W010 0888 VENT CONNECTION ASSEMBLY 33 W290 0076 VENT CONNECTION ASSEMBLY GASKET 46ACCESSORIES46 REF NO PART NO DESCRIPTION 37 W690 0001 MILLIVOLT THERMOSTAT 38...

Page 22: ...22 W415 0318 03 05 09 20 40 43 44 42 1 5 8 7 6 45 22 2 11 3 46 47 12 15 18 16 17 13 14 32 34...

Page 23: ...n Remote wall switch is grounding Remote wall switch wire is grounding Faulty valve Turn up the pilot flame Replace pilot assembly Clean thermopile connection tot he valve Reconnect Replace thermopile...

Page 24: ...ctrode tip and the pilot burner To ensure proper electrode location tighten securing nut finger tight plus 1 4 turn Check that the manual valve is turned on Check the pilot orifice for blockage Replac...

Page 25: ...18 03 05 09 TP SERVICE HISTORY 10 0 SERVICE HISTORY Appliance Service History This heater must be serviced annually depending on usage Date Service Technician Name Service Performed Special Concerns D...

Page 26: ...26 W415 0318 03 05 09 TP NOTES 11 0 NOTES...

Page 27: ...27 W415 0318 03 05 09...

Page 28: ...28 W415 0318 03 05 09...

Reviews: