EN
troubleshooting
Motor is turning,
frequent beeping
Receiver batteries low.
-
Replace batteries.
occurs.
Lights or blower
Control module switch in
-
Verify ON/OFF switch is in the “I” position which denotes on.
won’t function (if
equipped).
wrong position.
COM switch is unplugged.
-
Verify “COM” switch is plugged into the front of the control
module.
Flames are very
aggressive.
Door is ajar.
-
Ensure door is secured properly.
Venting action is too great.
-
Check to ensure venting is properly sealed or restrict vent
exit with restrictor plate. (Not available in all appliances).
Appliance won’t per-
No power to the system.
-
Check breaker to verify it’s in the “
on
” position.
form any functions.
Receiver switch in wrong
position (if equipped).
-
Verify that the 3 position switch on the receiver is in the
remote position (middle).
Transmitter
isn’t operational.
-
Check battery power and battery orientation.
The following applies specifically to the SIT system only:
Pilot will not light.
Makes no noise with
no spark at pilot
burner. (Lights and
blower operate, if
equipped).
Ignition box has been locked
out.
Choose one of the 4 methods below to reset the system.
1.
To reset ignition box when locked out. Turn off power supply
and remove batteries (if used) from the back up battery pack.
2.
To reset the DFC Board when the board goes into a lock
out condition and the LED is blinking 3 times using the
transmitter
on/off
button:
Step 1:
Turn the system off by pressing the
on/off
button to turn the system off.
Step 2:
After approximately 2 seconds press the
on/
off
button on the transmitter again. The DFC Board will
reset and the ignition sequence will start again.
3.
To reset the DFC Board when the board goes into a lock out
condition and the LED is blinking 3 times by cycling flame:
Step 1:
In the manual flame control mode, use the down
arrow button to reduce the flame to off, indicated by the
word OFF displayed on the transmitter LCD screen.
Step 2:
Wait approximately 2 seconds and press the up
arrow button, the ignition sequence will start.
Starting from
off
, press the
on
button on the transmitter. Approximately 4 seconds
on/off
button is pressed, the ignition
board will start the spark. The first try for ignition will last approximately 60 seconds. If there is no flame ignition (rectification),
the board will stop sparking for approximately 35 seconds. After the wait time, the board will start the second try for ignition
by sparking for approximately 60 seconds. If there is still no positive ignition, the board will go into lock out.
note:
symptom
problem
test solution
symptom
problem
test solution