TOP OF
APPLIANCE
38 1/4"
(97.2cm)
minimum mantel clearances
Combustible mantel clearance can vary according to the mantel depth. Use the graph to help evaluate the clear-
ance needed.
MANTEL DIMENSIONS
Ref
Height
Depth
D
4" (102mm)
2” (51mm)
C
6" (152mm)
4” (102mm)
B
8" (203mm)
6” (152mm)
A
10" (254mm)
8” (203mm)
( " )
12
10
8
6
4
1 2 3 4 5 6 7 8 9 10
MANTEL DEPTH
alcove enclosure
( " )
RECESS OR
ALCOVE
AREA
ENCLOSURE
AREA
APPLIANCE
Non-combustible material can be used, provided the minimum clearances to combustible materials are applied.
The minimum enclosure volume must be increased by no less than the volume of the recess. This adjustment can
be made by increasing any or all of the height, width and depth of the enclosure.
Risk of fire. Maintain all specified air space clearances to combustibles. Failure to comply with these instructions
may cause a fire or cause the appliance to overheat. Ensure all clearances (i.e. back, side, top, vent, mantel,
front, etc.) are clearly maintained.
When using paint or lacquer to finish the mantel, the paint or lacquer must be heat resistant to prevent
discolouration.
•
•
!
WARNING
Recesses or alcoves above the appliance can be made as deep as desired provided the minimum clearances to
combustibles are maintained.
note: