3. External Connection
50
AD12-16(PCI)E, AD12-16U(PCI)E, AD16-16(PCI)E
Digital I/O signals and Control signals
Connection
The digital I/O signals and the control signals (external trigger input signal, sampling clock output
signal and so on) are interfaced through the connector CN2. User can use an optional flat cable DT/E1
or DT/E2 (with bracket and a 15-pin D-SUB female connector) to connect these signals to your external
devices.
All the digital I/O signals and control signals are TTL level signals.
10k
Ω
Input
Digital Ground
BOARD
CN2
Cable
Target
Figure 3.11. Digital Input Connection
Digital Ground
BOARD
CN2
Cable
Target
Output
I
OL
=24mA
Figure 3.12. Digital Output Connection
CAUTION
Do not short the output signals to analog ground, digital ground, and/or power line. Doing so may
damage the board.
Reference
For the operation timings for control signal input, see ”Timing of External Control Signals” in
Chapter 6 “Hardware”.