Functions of Components
IPC-BX/M560(PCW)
47
Table 5.10. Register Functions
<3/4>
MCR: Modem Control Register
D7
D6
D5
D4
D3
D2
D1
D0
03FCH
I/O address
Contents
DTR 0: Inactive [HIGH]
1: Active [LOW]
0
0
0
Loop IRQ
X
RTS DTR
RTS 0: Inactive [HIGH]
1: Active [LOW]
Interrupt control bit
0: Disable
1: Enable
Diagnostic local loopback test
0: Disable
1: Enable
LSR: Line Status Regester
03FDH
D7
D6
D5
D4
D3
D2
D1
D0
0
TEMT THRE
BI
FE
PE
OE
DR
Data ready
(1: Receive data present)
Overrun error (1:
Error occurred)
Parity error (1: Error occurred)
Framing error (1: Error occurred)
Break interrupt (1: Detects break status)
Transmitter holding register empty
(1: Transmission buffer empty)
Transmitter empty
(1: Both of the transmitter holding register and
transmitter shift register are empty.)
Summary of Contents for IPC-BX/M560
Page 1: ...BOX PC IPC BX M560 PCW User s Manual...
Page 11: ...IPC BX M560 PCW x...
Page 45: ...BIOS Setup IPC BX M560 PCW 34...
Page 89: ...A 46 056 LZJ2611 021030 990817...