Overview
IPC-BX/M560(PCW)
4
Table 2.2. Installation Environment Conditions
Power supply specifications
Allowable duration of
momentary power failure
Dielectric strength
3.0kVAC (input-output), 2.0kVAC (input-FG),
0.5kVAC (output-FG) for one minute each
Insulation resistance
50M
Ω
(500VDC)
Environment specifications
0-50ºC (with SDD)
Ambient operating temperature
0-45ºC (with HDD)
5-45ºC (with FDD)
Ambient storage temperature *1
-10~60ºC
Ambient humidity *2
20~90%RH
Floating dust
Normal
Corrosive gas
None
Line noise
AC line: 2kV, Signal line: 1kV (IEC1000-4-4Level 3, EN61000-4-4Level 3)
Contact: 4kV (IEC1000-4-2Level 2, EN61000-4-2Level 2)
Airborne: 8kV (IEC1000-4-2Level 2, EN61000-4-2Level 3)
10-50Hz/Single-side amplitude 0.15mm; 50-500Hz/2.0G
X/Y/Z directions for 23 minutes each
(Conforming to JIS C0040 and IEC68-2-6)
16.7Hz/2G, X/Y/Z directions for 30 minutes each
(Conforming to JIS C0040 and IEC68-2-6)
Impact resistance *3
10G in the X/Y/Z directions for 11ms; Half-sine wave
(Conforming to JIS C0041 and IEC68-2-27)
*1 When the BOX-PC is stored at an ambient temperature of 0ºC or less, the orientation of the main unit
is restricted. (See "Installation Conditions" in Chapter 3 "Hardware Setup".)
*2 Assuming that no floppy disk is used.
*3 Assuming that neither HDD nor FDD is used.
Electrostatic
durability
Requirement
20ms or less
Noise
resistance
Fixed vibration
endurance
Sweep durability
Vibration
resistance *3
Item
Summary of Contents for IPC-BX/M560
Page 1: ...BOX PC IPC BX M560 PCW User s Manual...
Page 11: ...IPC BX M560 PCW x...
Page 45: ...BIOS Setup IPC BX M560 PCW 34...