Supplying power through the UTP cable
The FX-DS540-AP can be powered by using the power supply separator unit (POW-SP20) and power
supply unit (POW-CB20 or POW-CBM4).
As the FX-DS540-APP contains a power supply separator unit (equivalent to the POW-SB20), it can be
powered directly from the power supply unit (POW-CB20 or POW-CBM4).
For details, refer to the manual for each model.
POW-CBM4
HUB
UTP cables are all straight cables.
(1)
(3)
POW-CBM4
HUB
POW-SP20
(1)
(2)
(3)
UTP cables are all straight cables.
Enlarged figure
UPLINK 8X 7X 6X 5X 4X 3X 2X 1X
FX-DS540-APP
(Power destination)
UTP
10/100
M
SmartMed
ia
BU
SY
POW
ER
WLI
NK
CO
M
FX-DS540-AP
(Power destination)
UTP
10/100
M
SmartMed
ia
BUS Y
POW
ER
WLI
NK
CO
M
OUT
+
UPLINK 8X 7X 6X 5X 4X 3X 2X 1X
AP
HUB
AP
HUB
Figure 3.13 Example of Connecting Using the pow-CBM4
CAUTION
-
The total length of UTP cables between the power destination and the hub must be a maximum of
90m. Adjust the lengths of cables so that “(1) + (2) + (3)” does not exceed 90 m.
-
Do not connect the AP-side UTP cable of the POW-CBM4 to a device such as a hub as doing so can
cause a device fault or accident.
-
Do not use the power supply unit along with the AC adapter bundled with the FX-DS540-APP.
-
Do not connect the AC cable of the FX-DS540-AP main unit.
-