4. Each Component Function
BX-100n User’s manual
41
* 4001h (bit4-6): Alarm out output control
---
WD_S0
R/W (Default: XXXX0000b)
WD_S1
PO2_M
PIM2
PIM1
PIM0
RESET
D6
D5
D4
D3
D2
D1
D0
D7
Figure 4.6. Alarm Out Output Control Port (4001h)
PO2_M
: PO PO2/WDT pin output setting
0
: Set the RAS connector's PO2/WDT(12) signal to PO2 (general-purpose output).
1
: Set the RAS connector's PO2/WDT(12) signal to alarm out.
Table 4.13. WD_S1, WD_S0: Alarm-out Output Status Settings
External alarm output status
WD_S1 WD_S0 When power is
turned off
When BIOS
starts
When
WDT starts
When time
expires on WDT
0 0
OFF
OFF
OFF
ON
1
0
OFF OFF ON OFF
1 1
OFF
ON
ON
OFF
0
1
OFF ON OFF ON
* 4002h: WDT control
R/W
D6
D5
D4
D3
D2
D1
D0
D7
Figure 4.7. WDT Control Port (4002h)
R : Cancels WDT stop/alarm.
Read data is undefined.
W : Start and clear the WDT
Write A5h to start and clear the WDT.
* 4003h: WDT counter
W
D6
D5
D4
D3
D2
D1
D0
D7
T6
T5
T4
T3
T2
T1
T0
T7
Figure 4.8. WDT Counter Port (4003h)
W : Writes watchdog timer count data.
Write watchdog timer counter expiration time data.
1sec
→
01h
8sec
→
08h
15sec
→
0Fh
30sec
→
1Eh
Summary of Contents for BX-100n-DC5000-C01
Page 1: ...IPC Series BOX PC for BX100n Series User s Manual CONTEC CO LTD...
Page 15: ...1 Introduction 8 BX 100n User s manual...
Page 23: ...2 System Reference 16 BX 100n User s manual...
Page 33: ...3 Hardware Setup 26 BX 100n User s manual...
Page 61: ...4 Each Component Function 54 BX 100n User s manual...