5. About Software 

 

 

 

64

 

AD12-8(PM) 

Sample Programs - Examples 

Analog input 

- SingleAi   

Perform single analog input from specified channel 

- MultiAi 

 

Perform single analog input from multiple channels 

- Ai  

 

Perform standard analog input using a FIFO buffer 

- AiPoll 

 

Perform standard analog input by polling 

- AiEx 

 

Perform analog input for multiple channels using a FIFO buffer 

- AiLong 

 

Perform long-duration analog input using a FIFO buffer 

- AiExt 

 

Perform analog input using an external clock 

- AiTrg 

 

Perform analog input using an external trigger to start and stop operation 

- AiLevel1   

Use a level trigger to start analog input 

- AiLevel2   

Use a level trigger to stop analog input 

- Ai2 

 

Perform standard analog input using more than one device 

 

Analog output 

- SingleAo   

Perform single analog output from specified channel 

- MultiAo 

 

Perform single analog output from multiple channels 

- Ao 

 

Perform standard analog output using a FIFO buffer 

- AoPoll 

 

Perform standard analog output by polling 

- AoEx 

 

Perform analog output for multiple channels using a FIFO buffer 

- AoLong 

 

Perform long-duration analog output using a FIFO buffer 

- AoExt 

 

Perform analog output using an external clock 

- AoRing 

 

Perform continuous analog output using a ring buffer 

- AoTrg 

 

Perform analog output using an external trigger to start and stop operation 

- Ao2 

 

Perform standard analog output using more than one device 

 

Digital input/output 

- DioBit 

 

Perform digital I/O using bit values 

- DioByte 

 

Perform digital I/O using byte values 

 

The actual types of sampling able to be performed depends on which functions your device 

supports. 

   

Summary of Contents for AD12-8(PM)

Page 1: ...PC HELPER Analog I O PC Card AD12 8 PM User s Guide CONTEC CO LTD ...

Page 2: ...owing list that your package is complete If you discover damaged or missing items contact your retailer Product Configuration List PC Card AD12 8 PM 1 Connection cable CB 37FS 1 PC Card Attachment CARD AT1 1set This User s Manual 1 CD ROM API PAC W32 1 CD ROM API PAC W32 PC Card Connection cable PC Card Attachment User s Manual User s Manual ...

Page 3: ...thout notice All relevant issues have been considered in the preparation of this document Should you notice an omission or any questionable item in this document please feel free to notify CONTEC CO LTD Regardless of the foregoing statement CONTEC assumes no responsibility for any errors that may appear in this document nor for results obtained by the user as a result of using this product Tradema...

Page 4: ...ent 7 Inspection 7 Storage 7 Disposal 7 2 SETUP 9 What is Setup 9 Using the PC Card under Windows Using the Driver Library API PAC W32 9 Using the PC Card under Windows Using Software Other than the Driver Library API PAC W32 10 Using the PC Card under an OS Other than Windows 10 Step 1 Installing the Software 11 Which Driver to Use 11 Starting the Install Program 12 When Using API AIO WDM 13 When...

Page 5: ...Using API AIO 98 PC 34 Setup Troubleshooting 37 Symptoms and Actions 37 If your problem cannot be resolved 37 3 EXTERNAL CONNECTION 39 Using the On board Connectors 39 Connecting a Device to a Connector 39 Connector Pin Assignment 40 Analog Input Signal Connection 41 Analog Output Signal Connection 42 Digital I O signals and Control signals Connection 43 Connecting an ATSS 16 Synchronized Sampling...

Page 6: ...Help File 62 Using Sample Programs 63 When Using API AIO 98 PC 65 Accessing the Help File 65 Using Sample Programs 66 Uninstalling the Driver Libraries 68 CD ROM Directory Structure 69 6 ABOUT HARDWARE 71 Hardware specification 71 Block Diagram 72 Control Signal Timings 73 ...

Page 7: ...vi AD12 8 PM ...

Page 8: ...icient for 16 384 data points This can be used to perform sampling in the background without affecting the PC processing performance Sampling control function For analog input The sampling clock that determines the sampling speed can be selected from either the internal sampling clock output from the internal clock generator or from an external sampling clock input from an external digital input A...

Page 9: ... advantage of the CONTEC hardware using various programming languages that support Win32 API functions such as Visual Basic and Visual C C It can also be used by the installed diagnosis program to check hardware operations CONTEC provides download services at http www contec co jp en to supply the updated drivers and differential files For details read Help on the bundled CD ROM or visit the CONTE...

Page 10: ...d cable with 37 pin D SUB connectors at either end PCB37PS 0 5P 0 5m PCB37PS 1 5P 1 5m Set of five 37 pin D SUB male connectors CN5 D37M Accessories Option Screw Terminal EPD 37 1 Termination Panel with BNC Connector for Analog I O Board ATP 8 Termination Panel M3 DTP 3 PC Termination Panel DTP 4 PC 1 Obtain a PCB37PS P cable separately recommended length 5m Check the CONTEC s Web site for more in...

Page 11: ...ce is returned freight prepaid with a copy of the original invoice and a Return Merchandise Authorization to the distributor or the CONTEC group office from which it was purchased This warranty is not applicable for scratches or normal wear but only for the electronic circuitry and original PC cards The warranty is not applicable if the device has been tampered with or damaged through abuse mistre...

Page 12: ...truction of equipment and resources Understand the meanings of these labels to operate the equipment safely DANGER DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION CAUTION indicates a potentially hazardous sit...

Page 13: ...PC card check that you are inserting the card with the correct orientation and that the card is inserted firmly Inserting the PC card incorrectly may damage the PC card or connector or result in a bad connection Ensure that the PC power supply has sufficient capacity for all mounted cards An inadequate power supply may cause misoperation overheating or faults The specifications of this product are...

Page 14: ...follows to use it safely Check that the bus connector and its cable have been plugged correctly The bus connector has no stain or corrosion Storage When storing this product keep it in its original packing form 1 Put the PC card in the storage bag 2 Wrap it in the packing material then put it in the box 3 Store the package at room temperature at a place free from direct sunlight moisture shock vib...

Page 15: ...1 Before Using the Product 8 AD12 8 PM ...

Page 16: ...ure to be performed before you can start developing application programs for the PC card using the bundled CD ROM Driver Library API PAC W32 Taking the following steps sets up the software and hardware You can use the diagnosis program later to check whether the software and hardware function normally Step 1 Installing the Software Step 2 Setting the Hardware Step 3 Installing the Hardware Step 4 ...

Page 17: ...wing parts of this manual as required This chapter Step 2 Setting the Hardware This chapter Step 3 Installing the Hardware Chapter 3 External Connection Chapter 6 About Hardware Using the PC Card under an OS Other than Windows For using the PC card under an OS other than Windows see the following parts of this manual This chapter Step 2 Setting the Hardware Chapter 3 External Connection Chapter 6 ...

Page 18: ...ove those provided by the previous API AIO 98 PC driver CONTEC recommends that you use the API AIO WDM driver for analog I O devices Although the API AIO WDM will support future OS versions and new devices there is no plan to support Windows NT4 0 Windows 95 the ISA bus or C bus If your require support for one of these please use the API AIO 98 PC driver The figure below shows a selection guide to...

Page 19: ... your PC 2 The API PAC W32 Installer window appears automatically If the panel does not appear run CD ROM drive letter AUTORUN exe 3 Click on the Install the drivers button CAUTION Before installing the software in Windows XP 2000 or NT log in as a user with administrator privileges ...

Page 20: ...all Type 2 Select the Functional Rich Analog API AIO WDM 3 Click on the Install button Clicking the Details button displays detailed information about API AIO WDM and API AIO 98 PC Run the installation 1 Complete the installation by following the instructions on the screen 2 The Readme file appears when the installation is complete ...

Page 21: ...lowing dialog box appears to select Driver Type and Install Type 2 Select Analog I O API AIO 98 PC W95 3 Select Driver and help files etc Development system 4 Click on the Install button Clicking the Details button displays detailed information about API AIO WDM and API AIO 98 PC ...

Page 22: ...d Display Readme file When installing the software and hardware for the first time 1 Clear the checkmark from the Perform hardware setup checkbox 2 Click the Finish button Proceed to step 2 to setup and install the hardware If the hardware is already installed Select the Perform hardware setup now API TOOL configuration checkbox and proceed to Step 4 Software Initial Setup You have now finished in...

Page 23: ...6 AD12 8 PM Step2 Setting the Hardware This section describes how to set the PC card and plug it on your PC Parts of the PC card Interface Connector 300mm AD12 8 PM Connection Cable PC Card Figure 2 1 Part Names ...

Page 24: ... shown in Figure 2 2 with the topside of the connector indicated by the arrow symbol aligned with the topside of the card CAUTION When plugging in the cable align the cable connector with the PC card socket and push firmly into place Do not apply any excessive force to the socket on the PC card as this may damage the socket or result in a bad connection Also never insert or unplug the connector wh...

Page 25: ...the connector Refer to the instructions supplied with the PC card attachment for details on how to fit it CAUTION When using other PC cards in the same PC the PC card attachment may obstruct the other cards and make them difficult to insert In this case please remove the PC card attachment PC Card PC Card Socket Side PC Card Attachment Figure 2 3 Fitting the PC Card Attachment ...

Page 26: ...n some PCs are oriented so that cards is inserted with the topside facing down Refer to the manual for your PC for instructions on how to remove the card Figure 2 4 Insert the PC Card CAUTION Take note of the following points as inappropriate handling of the PC card may damage the card or connector socket and may result in a bad connection Always insert the PC card with the correct orientation and...

Page 27: ...gs CAUTION The PC card cannot be properly installed unless the resources I O addresses and interrupt level for the PC card can be allocated Before attempting to install the PC card first determine what PC resources are free to use The resources used by each PC card do not depend on the location of the PCI bus slot or the PC card itself If you remove two or more PC card s that have already been ins...

Page 28: ...information INF file to register the PC card Source folder The setup information INF file is contained in the following folder on the bundled CD ROM INF WDM AIO You have now finished installing the hardware INF WDM AIO The name of the board you have just added is displayed AD12 8 PM ...

Page 29: ...API AIO 98 PC 1 The Add New Hardware Installation Wizard appears Select Specify driver location and click the Next button The New Hardware Installation Wizard does not appear on Windows NT 4 0 Proceed to PC Card Configuration Settings ...

Page 30: ...d Source folder The setup information INF file is contained in the following folder on the bundled CD ROM Windows XP 2000 INF Win2000 Aio PCCard Windows Me 98 95 INF Win95 Aio PCCard Example of specifying the folder for use under Windows Me The name of the board you have just added is displayed AD12 8 PM INF Win95 Aio PCCard ...

Page 31: ... dialog box appears only indicating that the relevant driver has not passed Windows Logo testing and it can be ignored without developing any problem with the operation of the PC card In this case click on the Continue Anyway button You have now finished installing the hardware The name of the board you have just added is displayed AD12 8 PM ...

Page 32: ...PAC W32 PCMCIA Configuration 2 From Add PC Card select AD12 8 PM 3 Reboot the PC 4 Restart the PC card configuration utility and check that the card and resources appear correctly in System check complete CAUTION If I O does not work correctly when checked using the diagnosis program double click on the PC card and specify the resource settings manually If the interrupt conflicts with another devi...

Page 33: ...ce Manager From My Computer Control Panel select System and then select the Device Manager tab You can also open Device Manager by right clicking on My Computer and selecting Properties 2 The installed hardware appears under the CONTEC Devices node Open the CONTEC Devices node and select the device you want to setup the device name should appear highlighted Click Properties The name of the board y...

Page 34: ...age and then click OK The device name you set here is used later when programming The initial device name that appears is a default value You can use this default name if you wish Make sure that you do not use the same name for more than one device You have now finished installing the initial setting of Software ...

Page 35: ...tart menu run Programs CONTEC API PAC W32 PCMCIA Configuration 2 API TOOL Configuration detects PC cards automatically The detected PC cards are listed Updating the Settings 1 Select Save settings to registry from the File menu You have now finished installing the initial setting of Software ...

Page 36: ... the PC card I O status and interrupt status Check Method Please connect analog signals when checking analog input output data The shown below Figures are examples of using 0 channel See Chapter 3 Connecting to External Devices for details on how to make the connection Connection diagram Analog input Analog output Signal Source e g Battery etc Analog Ground 20pin CH0 1pin Interface Connector teste...

Page 37: ...2 Setup 30 AD12 8 PM How to Use the Diagnosis Program When Using API AIO WDM Starting the Diagnosis Program Click the Diagnosis button on the device property page to start the diagnosis program ...

Page 38: ... select the desired output channel and output range from the lists You can set the output data to DC constant voltage sine wave or square wave Digital input output The upper row of circular lamps indicates the digital input states Red indicates the bit is ON and brown indicates OFF Clicking the lower row of switches turns the digital output bits ON or OFF ...

Page 39: ...ailed data including the device settings and settings for each channel to a text file and displays the file for you to view Clicking Diagnosis Report prompts you to specify where to save the report text file The name of the board you have just added is displayed AD12 8 PM ...

Page 40: ...2 Setup AD12 8 PM 33 2 The diagnosis report contains the following data Version of OS Device Information File Information Initialization interrupts current input or output state for each channel ...

Page 41: ...e the Diagnosis Program When Using API AIO 98 PC Starting the Diagnosis Program Select the PC card in the API TOOL Configuration windows then run the Diagnosis Program The name of the board you have just added is displayed AD12 8 PM ...

Page 42: ...hecking Analog Inputs and Outputs Analog input Select the input channel and input range from the lists Input data is plotted on a graph Analog output You can select the desired output channel and output range from the lists ...

Page 43: ...is results while saving them in text format The results are saved and displayed as a text file AioRep txt in the install folder CONTEC CONTECW95 The Diagnosis Program performs checking whether or not the PC card is present interrupt test driver file test and PC card settings test 2 A diagnosis report is displayed as shown below Click on Show Report ...

Page 44: ...O 98 PC use the PC card configuration utility to set the I O address manually The diagnostic program works correctly but the application program does not The diagnostic program uses the API TOOL functions If the diagnostic program works correctly other applications should work correctly also If you have a problem recheck your program taking note of the following points Check the return values of t...

Page 45: ...2 Setup 38 AD12 8 PM ...

Page 46: ...d 37 pin D SUB female connector 17JE 13370 02 D8C mfd by DDK equivalent Thumb screw UNC 4 40 inch screw Connector frame 17L 002C mfd by DDK UNC 4 40 inch screw Applicable connector 17JE 23370 02 D8C mfd by DDK Male FDCD 37P mfd by HIROSE Male DC 37P N mfd by JAE Male 37 36 21 20 19 18 2 1 Interface Connector Figure 3 1 Interface Connector and Applicable Cable Connector Option Cable PCA37P Option C...

Page 47: ...Input 0 Analog Input 7 Analog input signal The numbers correspond to channel numbers Analog Output 0 Analog Output 1 Analog output signal The numbers correspond to channel numbers Analog Ground Common analog ground for analog I O signals Digital Input 0 Digital Input 3 Digital input signal Digital Out 0 Digital Out 3 Digital output signal External Sampling Clock Input Input signal for external sam...

Page 48: ...rotection from noise For each analog input channel on CN1 connect the core wire to the signal line and connect the shielding to ground Analog Ground Shield cable Analog Input 0 15 CARD Connector Signal Source Figure 3 5 Single ended Input Connection Shield Cable CAUTION If the signal source contains over 1MHz signals the signal may effect the cross talk noise between channels If the PC card and th...

Page 49: ...g or if you want to provide better protection from noise For the CN1 analog output connect the core wire to the signal line and connect the shielding to ground Analog Ground Shield cable Analog Output CARD Connector Target Digital Multi Meter etc Figure 3 7 Analog Output Connection Shield Cable CAUTION If the PC card or the connected wire receives noise or the distance between the PC card and the ...

Page 50: ...rnal device using a cable such as a separately purchased flat cable PCA37P All the digital I O signals and control signals are TTL level signals Input Digital Ground CARD Connector Cable Target Figure 3 8 Digital Input and external sampling clock Connection Digital Ground CARD Connector Cable Target Output IOL 8mA Figure 3 9 Digital Output Connection CAUTION Do not short the output signals to anal...

Page 51: ...nput 4 Analog Ground Analog Input 5 Analog Ground Analog Input 6 Analog Ground Analog Input 7 Analog Ground Simultaneous Hold Output Digital Ground PIN No 1 20 2 21 3 22 4 23 5 24 6 25 7 26 8 27 35 34 Signal Name IN0 AGND IN1 AGND IN2 AGND IN3 AGND IN4 AGND IN5 AGND IN6 AGND IN7 AGND SHOLD GND PIN No 1 20 3 22 5 24 7 26 9 28 11 30 13 32 15 34 18 37 Figure 3 10 Example of connection wiring of ATSS ...

Page 52: ...res it in memory You can set a variety of conditions for analog input including the input channel sampling period and sampling start stop conditions Analog input processes are classified as follows Synchronized Sampling 5 Extended function 1 Setting the Conversion Condititions 2 Starting Stopping Operation 3 Monitoring the Status and Acquiring Data 4 Reset Clock Start Condition Stop Condition Even...

Page 53: ... segments When the device covers the range of 0 10 volts the minimum unit of converted voltages is 10 4096 2 44mV If the device has a resolution of 16 bit it is 10 65536 0 153mV instead AD12 8 PM The resolution is 12 bit Input Mode This device has single ended inputs only This cannot be changed Channel A channel indicates a single analog input point See Connector Pin Assignment in Chapter 3 for de...

Page 54: ... provided which check and report the state in which the memory has stored a fixed amount of data or in which the memory has become full The FIFO memory is used to obtain all input data from analog input in a short or infinite period of time Ring format In the ring format the memory contains storage areas arranged in a ring Input data items are written to the memory sequentially When it stores data...

Page 55: ...ata items are stored to the memory sequentially The repetition state can be subject to status monitoring and application notification The repeat function on the device cannot be used when the sampling start condition is set to software Clock The sampling clock controls the sampling frequency You can select either the internal sampling clock or external sampling clock The sampling clock is selected...

Page 56: ... input data Level comparison conditions are set as two conditions level and direction The above sketch shows that the level comparison condition is satisfied in the rising direction The start condition is satisfied when the analog signal at the specified channel passes the comparison level in the rising direction Input data items are stored to memory starting with those at solid dots The above ske...

Page 57: ...nd direction The above sketch shows that the level comparison condition is satisfied in the rising direction The stop condition is satisfied when the analog signal at the specified channel passes the comparison level in the rising direction Input data items are stored to memory ending until those at solid dots The above sketch shows that the level comparison condition is satisfied in the falling d...

Page 58: ...condition is software Repeat end event This even occurs whenever a repetition is completed End of device operation event This event occurs when the entire operation including repetitions is completed Stored specified sampling times event This event occurs when sampling has been performed for the number of times set by software This event can only be used in device buffer mode Specified number of t...

Page 59: ...tored This status is set to ON when input data stored in memory has reached the amount corresponding to the preset number of times of sampling If the memory format is FIFO the status is set to OFF when the amount of input data in the memory falls below the value corresponding to the preset number of times of sampling as data is acquired Once the status is set to ON when the memory format is ring i...

Page 60: ...red differently depending on the memory format used Data acquisition in FIFO format When FIFO memory is used the oldest data is always read first The following sketch shows an image of data acquisition in FIFO format When data is acquired from the memory the free memory space increases by that data size When data is acquired next the oldest one of the existing data items is taken from the memory i...

Page 61: ...can fetch the same data any number of times Conversion data The following equation represents the relationship between input data and voltage Voltage Input data x Max range value Min range value Resolution Min range value The value of resolution for the 12 bit device is 4096 that for the 16 bit device is 65536 The table below shows the relationship between input data and voltage in the 10 volt ran...

Page 62: ...llowing memory related states Resets the sampling count to 0 Sets the status indicating whether the specified number of samples have been saved to OFF Resets the buffer overflow status Resets the repeat count to 0 5 Extended function Synchronized Sampling Synchronized sampling performs AD conversion for multiple channels at the same time at the sampling clock timing You can use the ATSS 16 synchro...

Page 63: ...10 volts the minimum unit of converted voltages is 10 4096 2 44mV If the device has a resolution of 16 bit it is 10 65536 0 153mV instead AD12 8 PM The resolution is 12 bit The output range of AD12 8 PM is designed so that the minimum unit of the converted voltage may be set to 1mV Channel Channel represents each point of analog output For individual channel numbers see Using the On board Connecto...

Page 64: ...hannels starting from channel 0 The formula below gives the relationship between the output data and voltage on the AD12 8 PM Output data Voltage x 4096 4 096 The table below lists the output voltage for different output data values Voltage Output data 12 bit 4 095V 4095 20 49V 2049 2 048V 2048 2 047V 2047 0 0000V 0 Ex When 3V is output at a resolution of 12 bit Output data 3 4096 4 096 3000 ...

Page 65: ... 1 ON or 0 OFF of each input bit can be obtained by specifying the bit Input in Bytes Individual input bits can be input in byte units When the number of input points of the device is 4 the individual input bits are arranged as shown below and the byte data to be input is a value between 0 and 15 depending on the states of the bits EX Input of bit 3 OFF bit 2 ON bit 1 OFF and bit 0 ON Byte data 05...

Page 66: ...e state of each output bit can be changed to ON or OFF by specifying the bit and setting it to 1 or 0 Output in Bytes Individual output bits can be output in byte units When the number of output points of the device is 4 the individual output bits are arranged as shown below and byte data to be output is a value between 0 and 15 Ex Output of bit 3 ON bit 2 OFF bit 1 ON and bit 0 OFF Byte data 10 A...

Page 67: ...4 Functions 60 AD12 8 PM ...

Page 68: ...rnal or external sampling clock Simultaneous monitoring of the termination of analog input sampling buffer memory usage and interrupt events such as occurrences of errors Driver option check using a demo driver even without the PC card installed For details refer to the help file The help file provides various items of information such as Function Reference Sample Programs FAQs and Troubleshooting...

Page 69: ...62 AD12 8 PM When Using API AIO WDM Accessing the Help File 1 Click on the Start button on the Windows taskbar 2 From the Start Menu select Programs CONTEC API PAC W32 AIOWDM API AIO WDM HELP to display help information ...

Page 70: ...erence when writing your own programs To use the sample programs specify the device name in the property page for the program The sample programs are stored in Program Files CONTEC API PAC W32 AIOWDM Samples Running a Sample Program 1 Click on the Start button on the Windows taskbar 2 From the Start Menu select Programs CONTEC API PAC W32 AIOWDM SAMPLE 3 A sample program is invoked ...

Page 71: ...analog input using more than one device Analog output SingleAo Perform single analog output from specified channel MultiAo Perform single analog output from multiple channels Ao Perform standard analog output using a FIFO buffer AoPoll Perform standard analog output by polling AoEx Perform analog output for multiple channels using a FIFO buffer AoLong Perform long duration analog output using a FI...

Page 72: ...e AD12 8 PM 65 When Using API AIO 98 PC Accessing the Help File 1 Click on the Start button on the Windows taskbar 2 From the Start Menu select Programs CONTEC API PAC W32 AIO API AIO HELP to display help information ...

Page 73: ...API TOOL configuration utility You can use these to check the device operation and as a reference when writing your own programs The sample programs are stored in Program Files CONTEC API PAC W32 AIO Samples Running a Sample Program 1 Click on the Start button on the Windows taskbar 2 From the Start Menu select Programs CONTEC API PAC W32 AIO SAMPLE 3 A sample program is invoked ...

Page 74: ...ioInpBdMem and AioDO to perform simultaneous sampling using two devices each with on board memory AioInp This sample console application uses AioOpenEx and AioInp Analog output AO Uses AioOut to perform a single analog output AOBack Uses AioOutBack to perform analog output at fixed time intervals AioOut This sample console application uses AioOpenEx and AioOut Digital input output DIO Uses AioDO a...

Page 75: ...click on Add Remove Programs in the Control Panel 3 If using API AIO WDM select CONTEC API AIO WDM driver and CONTEC API AIO WDM VerX XX development system from the list of applications If using API AIO 98 PC select CONTEC API AIO 98 PC xx VerX XX development system and CONTEC API AIO 98 PC xx VerX XX development system Then click on the Add Remove button Follow the on screen instructions to unins...

Page 76: ...ormation on each API TOOL APIPAC AIO Disk 1 Disk 2 Disk N CNT FreeSamples Sample programs in Delphi and Builder Builder 1 0 HELP HELP file Aio Cnt INF OS specific INF file folder Windows 9X 2000 WDM Win2000 Win95 Readme Driver readme file folder Release For creation of a user specific install program API_NT API_W95 ...

Page 77: ...5 About Software 70 AD12 8 PM ...

Page 78: ...kΩ or more Resolution 12 bit Non Linearity error 1 2LSB Offset error 4LSB Gain error 3LSB Conversion speed 10μsec ch Max Inter channel time error 8 5μsec When multi channel mode set Buffer memory FIFO format 16 384 data Sampling clock Internal sampling clock 10 000 104 857 600nsec Specified in 100nsec increments External sampling clock TTL level falling edge Setup time 100nsec Hold time 100nsec An...

Page 79: ...300 mm Weight 120g 1 The non linearity error means an error of approximately 0 1 occurs over the maximum range at 0 C and 50 C ambient temperature Block Diagram AD12 8 PM ATTRIBUTE MEMORY ADDRESS BUS DATA BUS PCMCIA SLOT ANALOG INPUT ANALOG OUTPUT DIGITAL INPUT DIGITAL OUTPUT IORD IOWR WAIT IREQ RESET IOIS16 CE1 2 CD1 2 OE WE PGM REG INPACK STSCHG BUFFER MEMORY PCMCIA CONTROL LOGIC AIO DIO CONTROL...

Page 80: ...Control Signal Timings Parameter Symbol Time nsec Setup time for falling edge of external sampling clock signal tDEH 100 Hold time for falling edge of external sampling clock signal tDEC 100 Delay from falling edge on external sampling clock signal until AD conversion starts on first channel tSRS 100 CAUTION The times listed in Table 6 2 are for standard operating conditions ...

Page 81: ...5 0025 Japan Japanese http www contec co jp English http www contec com Chinese http www contec com cn No part of this document may be copied or reproduced in any form by any means without prior written consent of CONTEC CO LTD 03312008 11291995 Management No A 41 461 03312008_rev6 Parts No LZU1552 ...