4. Functions
48
AD12-8(PM)
Repeat
”Repeat” indicates the number of repetitions of sampling to be executed, from when the sampling start
condition is satisfied until the end of sampling, including delayed sampling.
The number of repetitions is set by means of software, for which conversion is repeated. You can set
an infinite number of repetitions, in which case the conversion is terminated by the software abort
command.
Input data items are stored to the memory sequentially. The repetition state can be subject to status
monitoring and application notification.
The repeat function on the device cannot be used when the sampling start condition is set to software.
Clock
The sampling clock controls the sampling frequency. You can select either the internal sampling clock,
or external sampling clock
The sampling clock is selected by means of software.
-
Internal sampling clock
This uses the signal from the clock generator on the device.
- External
sampling
clock
The edge of the digital signal input from an external device is used for the sampling clock.