Page 50
15/09/2004
PS8149KENAA01
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
SUB-NETWORK ADD
The number of the sub-network and the number of the set on the sub-network.
The sub-network address and IP address must respect the following relations:
♦
if the first bit of the IP address is 0 (class A), the sub-network address must be in
the form: 255.xxx.xxx.xxx,
♦
if the first 2 bits of the IP address are 10 (class B), the sub-network address must
be in the form: 255.255.xxx.xxx,
♦
if the first 3 bits of the IP address are 110 (class C), the sub-network address must
be in the form: 255.255.255.xxx.
SELECT THE IP BOARD
Using the space bar, select in this drop-down menu the position of a card to display and
modify its characteristics. Press
Enter to confirm.
Note:
Position 0-04 indicates the IP address position on the CPU card.
IP BOARD PARAMETRES 0-04
IP ADDRESS
131.129.255.53.
MASK 255.255.255.224
DEFAULT ROUTER
131.129.255.33.
UDP
PORT
40000
TCP PORTS: FIRST NUMBER 41000
LAST NUMBER 41999
ETHERNET ADDRESS
08-00-71-09-80-2D
LINK TYPE 10 Mb HALF DUPLEX
----------------------------------------
Figure 28: IP card selection
The title indicates the card's position (cabinet number and position of the card in the
cabinet).
IP ADDRESS
Card IP address on 4 bytes.
Example:
192.42.11.154
Example:
0.0.0.0, 255.255.255.255 and 127.0.0.1 are not valid addresses.
Note:
The decimal value of the first byte must not be greater than 223; if it is, the MMC
displays the message: ‘ SYNTAX ERROR ’.