PS8149KENAA01
15/09/2004
Page 147
Ce document est la propriété de EADS et ne doit pas être reproduit ou communiqué sans autorisation.
This document is the property of EADS and may not be copied or circulated without authorisation.
4.7.8
CAC SERVER MONITORING (MENU 4-7-8)
For the Call Manager (F5): Menu 4-7-3 (CAC server monitoring)
CAC SERVER MONITORING
1 DISP. FLOW TOWARDS OTHER CENTRES
2 DISP. FLOW PER CLASS
3 CENTERS COUNTERS REINITIALIZATION
4 CENTERS COUNTERS REINITIALIZATION
5 CAC SERVERS STATUS
ENTER
YOUR
CHOICE
.
--------------------------------------------
Figure 127: CAC server monitoring
This menu is used to access the menus for displaying and resetting current flow tables for
the active server.
Note:
The active server is the server used to control inter-centre and/or intra-class
flows. The server name may therefore be either the main server or secondary
server.
4.7.8.1
DISPLAYING FLOWS TOWARDS OTHER CENTRES (MENU 4-7-8-1)
For the Call Manager (F5): Menu 4-7-3-1 (Disp. flow towards other centres)
IMPORTANT:
This menu only appears if the PBX is configured in multi-site mode
(menu 3.6 - Parameters management).
DISP. FLOW TOWARDS OTHER CENTRES
ACTIVE SERVER: 001-SITE LOC, CCU: 2
CENTER
FLOW
MAX.
NO CRIT
NB REF
-----------------------------------------------------------
02-center
2
0*
0*
0
0
03-center
3
0
0
0
0
04-center
4
0
0
0
0
-----------------------------------------------------------
Figure 128: Display flows towards other centres
This menu is used to display the current server counters on a centre-by-centre basis.
Only the counters of the centres to which the flow is limited are displayed. These counters
are read in the active server