background image

7

4. Configuration of CM1000

4.1 The Service code

The Service code is used for CM1000’s advanced settings such as changing the Master 

code and Service code, LED indications and much more. The overview  of the settings 

and the factory settings can be seen in 4.2 Configuration overview.

The Service code is 

12347890 (factory setting).

Note: Before the Service code can be used must the voltage be turned OFF and 

ON (the Service code can now be entered within 10 seconds).

After entering the Service code the reader is in programming mode (the green LED 

lights). Each time a setting is made the CM1000 goes back to the previous point and 

the next setting can be made.

The navigation is by entering the position/ value followed by 

#.

4.2 Configuration overview

Position 

Setting 

   Factory 

default

00 

 

Master code (1 til 8 cifre) 

4711

01 

 

Service code (1 til 8 cifre) 

12347890

02 

 

LED indications   

 

Normal = Yellow, active = Yellow and green

03 

 

Outputs 

 

 

 

Output time for 1 and 2 is 5 seconds

04 

 

Special functions

05 

 

Smart reading

06 

 

Background light

08 

 

Backup/cloning the settings

2500   

Alle codes/Mifare tags on the user positions are deleted

0250   

Reset to factory default

4.3 Change the Master code

By default the Master code is 

4711 and can only be used to program, change or delete 

users on the CM1000.

To change the Master code, enter the following:

#

Key in the

Service code

#

Key in

00

#

Key in a new 

code or show tag

Summary of Contents for 480010

Page 1: ...User manual CM1000_usermanual_ENGjan17 Code Mifare CM1000 Mykey Art No 480010 black 480011 white Classic Art No 482010 black 482011 white...

Page 2: ...Configuration of CM1000 4 1 Service code 4 2 Configuration overview 4 3 Change the Master code 4 4 Change the Service code 4 5 LED Indications 4 6 Outputs 4 7 Special settings 5 Backup card 6 Blockin...

Page 3: ...ant from each other so the CM1000 can give access by code and Mifare tag The CM1000 is a stand alone unit that can be programmed directly by Master code and Service code 2 Installation Mount the reade...

Page 4: ...1 190 Activates output 1 and 2 191 200 Reserved for special functions 3 2 Programming user codes The Master code is used to program change delete the users By default the Master code is 4711 LED indic...

Page 5: ...11 standard For more tags continue from key in the user position or type to exit Changing Mifare tags It s the same procedure as programming new users just overwrite the position Delete a specific Mif...

Page 6: ...switch on only Ie the door is permanently unlocked when the code Mifare tag is entered Programming the same user 4 times By programming the same code Mifare tag on the same position 4 times the outpu...

Page 7: ...goes back to the previous point and the next setting can be made The navigation is by entering the position value followed by 4 2 Configuration overview Position Setting Factory default 00 Master code...

Page 8: ...n normal adjust the LED s for correct code tag indication active adjust the keying indication how the LED will react while keying To adjust the LED s press on the following yellow LED toggle by press...

Page 9: ...r seconds is the value automatically 0 which corresonds to set the output as toggle bonding the positions and output 1 bonding the positions and output 2 Both outputs are bonded to specific positions...

Page 10: ...and Mifare tags only activate output 2 High Security High Security increases the CM1000 s security by ensuring 2 positions have to be acti vated before the output is activated the positions must be ne...

Page 11: ...e yellow and brown wire Turn the voltage on 9 25 VDC the readers LED s lights and the buzzer sounds Turn the voltage off and disconnect the yellow and brown wire The CM1000 is now reset to factory def...

Page 12: ...9 Connection examples Direct connection Relay connection Thank you for choosing Conlan s products For further assistance please contact our support service...