3.4 Programming codes/Mifare tags for special functions

Programming the codes and Mifare tags is described in 3.2 and 3.3. This entry acti-

vates the output(s) for 5 seconds (factory setting). Only 1 user can enter at the time.

Programming the same user twice

By programming the same code/Mifare tag on the same position twice toggles the 

output.

(Ie. the code/Mifare tag is entered to unlock the door and entered to lock it again).

Programming the same user 3 times

By programming the same code/Mifare tag on the same position 3 times, the output is 

designated as switch on only.

(Ie. the door is permanently unlocked when the code/Mifare tag is entered).

Programming the same user 4 times

By programming the same code/Mifare tag on the same position 4 times, the output is 

designated as switch off only.

(Ie. the door is only locked when the code/Mifare tag is entered).

3.5 Smart reading

This position makes it possible to program codes/Mifare tags quickier without enter-

ing new positions. Key in a position and it counts automatically to the next position. 

Codes and Mifae tags can be programmed alternatively as you see fit.

*

*

 FFF

FFF

*

*

 FFF

FFF

For more 

codes/tags 

repeat from 

here

Note: This programming mode overwrites existing positions.

#

Key in the

Master code

#

Key in

05

#

Key in the start-

ing position

#

Key in the code 

or show tag

Summary of Contents for 480010

Page 1: ...User manual CM1000_usermanual_ENGjan17 Code Mifare CM1000 Mykey Art No 480010 black 480011 white Classic Art No 482010 black 482011 white...

Page 2: ...Configuration of CM1000 4 1 Service code 4 2 Configuration overview 4 3 Change the Master code 4 4 Change the Service code 4 5 LED Indications 4 6 Outputs 4 7 Special settings 5 Backup card 6 Blockin...

Page 3: ...ant from each other so the CM1000 can give access by code and Mifare tag The CM1000 is a stand alone unit that can be programmed directly by Master code and Service code 2 Installation Mount the reade...

Page 4: ...1 190 Activates output 1 and 2 191 200 Reserved for special functions 3 2 Programming user codes The Master code is used to program change delete the users By default the Master code is 4711 LED indic...

Page 5: ...11 standard For more tags continue from key in the user position or type to exit Changing Mifare tags It s the same procedure as programming new users just overwrite the position Delete a specific Mif...

Page 6: ...switch on only Ie the door is permanently unlocked when the code Mifare tag is entered Programming the same user 4 times By programming the same code Mifare tag on the same position 4 times the outpu...

Page 7: ...goes back to the previous point and the next setting can be made The navigation is by entering the position value followed by 4 2 Configuration overview Position Setting Factory default 00 Master code...

Page 8: ...n normal adjust the LED s for correct code tag indication active adjust the keying indication how the LED will react while keying To adjust the LED s press on the following yellow LED toggle by press...

Page 9: ...r seconds is the value automatically 0 which corresonds to set the output as toggle bonding the positions and output 1 bonding the positions and output 2 Both outputs are bonded to specific positions...

Page 10: ...and Mifare tags only activate output 2 High Security High Security increases the CM1000 s security by ensuring 2 positions have to be acti vated before the output is activated the positions must be ne...

Page 11: ...e yellow and brown wire Turn the voltage on 9 25 VDC the readers LED s lights and the buzzer sounds Turn the voltage off and disconnect the yellow and brown wire The CM1000 is now reset to factory def...

Page 12: ...9 Connection examples Direct connection Relay connection Thank you for choosing Conlan s products For further assistance please contact our support service...

Reviews: