3.4 Programming codes/Mifare tags for special functions
Programming the codes and Mifare tags is described in 3.2 and 3.3. This entry acti-
vates the output(s) for 5 seconds (factory setting). Only 1 user can enter at the time.
Programming the same user twice
By programming the same code/Mifare tag on the same position twice toggles the
output.
(Ie. the code/Mifare tag is entered to unlock the door and entered to lock it again).
Programming the same user 3 times
By programming the same code/Mifare tag on the same position 3 times, the output is
designated as switch on only.
(Ie. the door is permanently unlocked when the code/Mifare tag is entered).
Programming the same user 4 times
By programming the same code/Mifare tag on the same position 4 times, the output is
designated as switch off only.
(Ie. the door is only locked when the code/Mifare tag is entered).
3.5 Smart reading
This position makes it possible to program codes/Mifare tags quickier without enter-
ing new positions. Key in a position and it counts automatically to the next position.
Codes and Mifae tags can be programmed alternatively as you see fit.
*
*
FFF
FFF
*
*
FFF
FFF
For more
codes/tags
repeat from
here
Note: This programming mode overwrites existing positions.
#
Key in the
Master code
#
Key in
05
#
Key in the start-
ing position
#
Key in the code
or show tag