SK-4131-SPSQ 

Split Series Keypad with  

Proximity Card Reader 

Manual 

 

 

Split series installation for added 

security 

 

Up to 1,000 possible user codes 

and/or proximity cards 

 

12~24 VDC Operation, auto-adjusting 

 

Tamper output 

 

Keypad illuminates when a button is 

pressed 

Summary of Contents for ENFORCER SK-4131-SPSQ

Page 1: ...ad with Proximity Card Reader Manual Split series installation for added security Up to 1 000 possible user codes and or proximity cards 12 24 VDC Operation auto adjusting Tamper output Keypad illumin...

Page 2: ...de This page is for installers looking to do a basic installation and programming of the keypad For more in depth installation and programming instructions see the Table of Contents on page 4 Mounting...

Page 3: ...dicates the keypad is in programming mode If the keypad is set for Auto Code Entry Mode all codes will need to be the same number of digits as the master code see page 28 1 Power on the keypad and con...

Page 4: ...Common User Codes 19 20 Programming User Codes and Proximity Cards 20 21 Programming Visitor Codes for Output 1 22 Programming Duress Codes 23 24 Programming the Output Mode and Output Timing 25 Prog...

Page 5: ...s are programmed directly from the keypad No need for an external programmer EEPROM Memory protects programmed information in case of power loss Up to 50 01 50 duress codes for output 1 10 01 09 for o...

Page 6: ...the back box 5 Refer to the wiring diagram on pages 8 9 and connect the wires 6 Finish assembly by attaching the keypad to the back box with the included screws Controller SK 4131 SPCQ 1 Find a suita...

Page 7: ...ady Available for free connection Green Keypad locked Red Output 1 inhibited Red Programming mode Output 1 activated Green Output 2 activated Red Flashing Inhibit mode paused Red Standby mode Keypad S...

Page 8: ...a professional installer to reduce the risk of improper installation 4 The user s guide for this keypad is located on page 35 of this manual Be sure to store this manual in a safe place for future re...

Page 9: ...f needed so that if one keypad is used to open a door the other is temporarily disabled 10 Door Sensor Connect to an optional N C sensor such as a magnetic contact to monitor if a door is open or clos...

Page 10: ...ER Split Series Keypad with Proximity Card Reader 10 SECO LARM U S A Inc Sample Applications In this application the keypad is connected to a single door lock and an egress pushbutton Stand Alone Door...

Page 11: ...N C device to detect whether a door is opened or closed Do this for the two doors being protected Interlock system using two Split Series Keypads An interlock system needs two door controllers This ap...

Page 12: ...longer than the programmed time See Programming the Door Propped Open Warning and Timing on page 31 Door Open Alarm The controller will activate the alarm output and siren whenever the door is opened...

Page 13: ...for 10 seconds whenever a key is touched You may use it to turn ON an LED lamp and for a small buzzer to notify a guard or to energize a relay to switch ON lights or trigger a CCTV Camera to start rec...

Page 14: ...es Assigned to specific users as a way to send a silent alert if forced to use the keypad under duress 2 Proximity card only Standard 125kHz EM125 proximity cards can be used to activate output 1 outp...

Page 15: ...g Mode All programming of the keypad is done in programming mode 1 Enter the programming mode NOTE is the master code is the default master code see Programming the Master Code on page 17 to program a...

Page 16: ...for output 3 5 Second output momentary 25 55 System real time clock No default must be programmed 26 56 Output 1 auto disable time No default must be programmed 26 27 60 Wrong code system lock up Lock...

Page 17: ...e The master code does not serve as a user code for activating outputs 1 2 or 3 1 Make sure the keypad is in programming mode see Enter and Exit Programming Mode on page 15 2 Enter new master code NOT...

Page 18: ...elete a super user code 1 Make sure the keypad is in programming mode see page 15 2 Enter Using the Super User Code In these examples assume the super user code is 1 Activate or deactivate output 1 ti...

Page 19: ...le or enable output 1 toggle regardless of programming NOTE For more information on programming timed or toggle mode see Programming the Output Mode and Output Timing on page 25 The left LED will rema...

Page 20: ...ble security levels for the SK 4131 SPSQ Card only The most basic convenient level of security Just tap a previously programmed proximity card over the keypad to activate outputs 1 2 or 3 NOTE The dur...

Page 21: ...ge 28 The master super user common user visitor duress and user codes cannot be the same Examples 1 Program only a proximity card for user ID 017 for output 1 READ CARD 2 Program a user code for user...

Page 22: ...l other codes if the keypad is used in auto code entry mode see Programming the User Code Entry Mode on page 28 All visitor codes are deleted if power is lost Examples 1 Set the visitor ID 01 code to...

Page 23: ...s are programmed see Programming User Codes and Proximity Cards on pages 20 21 The duress code should be easy to remember For instance it can be the same as a user s normal user code but with a single...

Page 24: ...cannot deactivate the duress output Only a normal user code card super user code or a master code can deactivate the duress output NOTE A duress code can also be used in conjunction with a user card...

Page 25: ...this general formula Output Output Mode and Time Outputs Output 1 Output 2 Output 3 Output Mode and Time Start stop toggle mode In this case the output starts when a user code and or user card is ente...

Page 26: ...er reset the real time clock or clear the output 1 auto disable time If the output 1 auto disable time is not programmed losing power will not cause the keypad to beep To ensure accurate time it is ad...

Page 27: ...disable time When programming the output 1 auto disable time use this general formula Program Output 1 Auto Disable Time Start Time End Time Start Time Start time for output 1 auto disable time repre...

Page 28: ...System Lock Up Lock Options Lock Options Choose from several different options for the wrong code system lock up security level After 10 successive false attempts using incorrect user codes or user c...

Page 29: ...lt To enable keypad silent mode NOTE This programming function only impacts the keypad sounds It does not impact the output relay activation sounds see Programming the Output Relay Activation Sounds b...

Page 30: ...to 999 seconds Door forced open warning OFF default Door forced open warning ON NOTE represents the beep siren and alarm output active time which can be set from 1 to 999 seconds If programmed for do...

Page 31: ...magnetic contact or other door monitoring device the controller can be programmed to trigger the alarm output and siren for 1 to 999 seconds if the door is opened In this case if the alarm output is t...

Page 32: ...no audible warning Momentary contact with warning beep Press the egress button momentarily The keypad and controller will beep for the programmed delay time before letting the door open to warn that s...

Page 33: ...the keypad how long to wait after the egress button is pressed before activate output 1 Examples 1 Momentary mode Press the egress button and the keypad and controller will beep for 5 seconds before...

Page 34: ...nnect the power The keypad will beep repeatedly for one minute 4 While the keypad is beeping move the DAP jumper to the ON position then back to the OFF position once to stop the beeping 5 Enter the D...

Page 35: ...ccepted and the keypad is waiting for the Common user code 1 Long beep indicates that the door can be opened Security Level 4 Card Unique user code READ CARD 2 Short beeps and a rapidly flashing amber...

Page 36: ...ligation of SECO LARM and the purchaser s exclusive remedy shall be limited to the replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral inc...

Reviews: